Vestil FM-2572 handleiding
Handleiding
Je bekijkt pagina 17 van 20

Table of Contents 2/2/21 FM, MANUAL.DOCX
Table of Contents Copyright 2020, Vestil Manufacturing Corp. Page 17 of 20
INSPECTION AND MAINTENANCE
Proper maintenance is essential for maximizing the service life of the unit. If an inspection reveals any
irregularities in the condition of the unit, repair it before returning it to service. Only use manufacturer-approved
replacement parts. Contact Technical Service if you have questions that are not addressed in these
instructions or if you are uncertain how to address an issue discovered during an inspection. Technical Service
can be reached by calling (260) 665-7586 and asking for the Service and Parts Department or by submitting
questions online at http://www.vestilmfg.com/parts_info.htm.
1. Initial inspection. Prior to use, any new, altered, modified, or repaired dock leveler shall be inspected
by a qualified person. Examine the unit for damage such as cracked metal, cracked welds, severe rusting or
corrosion. Repair damaged welds. Appropriately patch damaged metal. Closely examine the mounting plates
and anchor points, since they are in direct contact with the dock. Make sure that all anchor bolts are tightly
fastened to the dock. Check for free motion in the hinges. Apply a general-purpose grease lubricant through
the grease nipples in both hinges. Check hinges for freedom of motion. Make sure all labels are in place & in
easily readable condition. See Labeling diagram on p. 19.
2. Frequent inspection. At the beginning of every shift, a designated person shall clean dirt, debris, and
fluids from the tread plate surfaces.
3. Periodic inspection. Monthly inspections by a qualified person are recommended for normal use of the
dock leveler.
3.1. Examine the unit for damage such as cracked metal, cracked welds, severe rusting or
corrosion. Repair damaged welds. Appropriately patch damaged metal. Closely examine the mounting
plates and anchor points, since they are in direct contact with the dock. Gently remove any
rust/corrosion and clean the affected areas. Apply touchup paint to the areas as soon as they dry.
3.2. Make sure that all anchor bolts are tightly fastened to the dock.
3.3. Clean dirt and debris from all surfaces to keep the finish in good condition. Slippery
substances, such as grease and oil, must be cleaned from the unit as soon as contact occurs. Apply
touchup paint to all areas where the finish is damaged.
3.4. Check for free motion in the hinges. Apply a general-purpose grease lubricant through the
grease nipples in both hinges. Check hinges for freedom of motion.
3.5. Check the spring tension by operating the dock leveler. See page 18 for instructions on
adjusting spring tension.
3.6. Make sure all labels are in place and are in a readable condition. See the Labeling diagram on
p.19.
ADJUSTING SPRING TENSION
The Edge-O-Dock leveler incorporates a spring counterweight to reduce the effort required to lift the dock
plate. It may be necessary to adjust the spring tension occasionally. This task requires two people to complete.
Bekijk gratis de handleiding van Vestil FM-2572, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vestil |
Model | FM-2572 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 4509 MB |