Vestil EPT-2547-30 handleiding

58 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 27 van 58
TABLE OF CONTENTS 5/19/2022 EPT MANUAL
TABLE OF CONTENTS Copyright 2021 Vestil Manufacturing Page 27 of 58
ISSUE
CAUSE
REMEDY
Unit will not reverse; belly switch
does not function; forward ok
Broken wire, or loose
connection, bad throttle
assembly, bad motor
controller.
Locate Pin 12 on Molex
connector at the motor controller.
Try to drive the unit in reverse,
there should be 24 volts at this
pin. If there is voltage and the
unit does not move, the motor
controller may be bad, consult
factory. If there is no voltage,
trace the wiring back towards the
tiller head and check voltage on
each side of connectors.
Continue this until bad connection
is found. If the connections are
all good, and there is no voltage
coming out of throttle assembly,
then the throttle assembly may be
bad. Verify there is 24 volts going
into the assembly, and that there
is a good ground. If there is still
no output voltage for pin 12,
replace throttle assembly.