TABLE OF CONTENTS 5/19/2022 EPT MANUAL
TABLE OF CONTENTS Copyright 2021 Vestil Manufacturing Page 25 of 58
ISSUE
CAUSE
REMEDY
Unit will not reverse; belly switch
does not function; forward ok
Broken wire, or loose connection,
bad motor controller
Bad throttle assembly
Locate Pin 12 on Molex connector
at the motor controller. Try to drive
the unit in reverse, there should be
24 volts at this pin. If there is
voltage and the unit does not move,
the motor controller may be bad,
consult diagnostics page/factory. If
there is no voltage, trace the wiring
back towards the tiller head and
check voltage on each side of
connectors. Continue this until bad
connection is found.
If the connections are all good, and
there is no voltage coming out of
throttle assembly, then the throttle
assembly may be bad. Verify there
is 24 volts going into the assembly,
and that there is a good ground. If
there is still no output voltage for pin
12, replace throttle assembly. See
Fig. 1
Belly switch does not function;
forward ok; reverse ok
Broken wire, or loose connection,
bad motor controller
Bad belly switch
Locate Pin 13 on Molex connector
at the motor controller. Try to drive
the unit in reverse, and hit the belly
switch… there should be 24 volts at
this pin. If there is voltage and the
unit does not move, the motor
controller may be bad, consult
diagnostics page/factory. If there is
no voltage, trace the wiring back
towards the tiller head and check
voltage, or continuity on each side
of connectors. Continue this until
bad connection is found.
If the connections are all good, and
there is no voltage, then the switch
may be bad. Verify there is 24 volts
going into the switch. If there is still
no output voltage for pin 13, replace
the switch.
Unit will not reverse. The unit
only goes forward for about 1
second and dies when the
handle is pulled down. When the
handle is re-set and pulled down
the unit will move forward again
then die.
Stuck Switch
The belly switch is stuck on. Tap
the orange assembly to see if the
switch can be freed. If this doesn’t
work, disassemble the tiller head by
removing 3 screws from bottom.
Slightly loosen up the two scews
that hold the switch in place, this
may free the switch. If it is still
stuck, contact the factory for a
replacement switch.