TABLE OF CONTENTS 5/19/2022 EPT MANUAL
TABLE OF CONTENTS Copyright 2021 Vestil Manufacturing Page 24 of 58
ISSUE
CAUSE
REMEDY
Unit will not go forward, or
reverse, but belly switch still
functions properly.
Broken wire, or loose connection,
bad motor controller,
Throttle assembly bad
Locate Pin 6 on Molex connector at
the motor controller. Try to drive
the unit in forward, there should be
0 to 5 volts (5V is full throttle) at this
pin. If there is voltage and the unit
does not move, the motor controller
may be bad, consult diagnostics
page/factory. If there is no voltage,
trace the wiring back towards the
tiller head and check voltage on
each side of connectors. Continue
this until bad connection is found.
If the connections are all good, and
there is no voltage coming out of
throttle assembly, then the throttle
assembly may be bad. Verify there
is 24 volts going into the assembly,
and that there is a good ground. If
there is still no output voltage for pin
6, replace throttle assembly. See
Fig. 1; also see p. 32-36.
Unit will not move forward, or
reverse, and the Belly switch will
not function, unit does turn on as
indicated by the battery gage
lighting up.
Blown fuse
Broken wire, or loose connection
Verify fuses are good, replace if
blown.
Locate Pin 7 on Molex connector at
the motor controller. Trace wire
back up to tiller head and verify
continuity all the way to the throttle
assembly. Repair any loose
connections.
If there is continuity up to the
throttle assembly, then check the
ground wire that comes off of B- on
the motor controller (3
rd
terminal
down). Add more length to this wire
if necessary, and re-terminate with
a ring terminal.
Unit will not go forward; belly
switch works; reverse works.
Broken wire, or loose connection,
bad motor controller
Bad throttle assembly
Locate Pin 11 on Molex connector
at the motor controller. Try to drive
the unit in forward, there should be
24 volts at this pin. If there is
voltage and the unit does not move,
the motor controller may be bad,
consult diagnostics page/factory. If
there is no voltage, trace the wiring
back towards the tiller head and
check voltage on each side of
connectors. Continue this until bad
connection is found.
If the connections are all good, and
there is no voltage coming out of
throttle assembly, then the throttle
assembly may be bad. Verify 24
volts going into the assembly, and
that there is a good ground. If there
is still no output voltage for pin 11,
replace throttle assembly. See
pages 32-36.