ISSUE
CAUSE
REMEDY
Unit will not raise; motor does not
run
Loose wire
Bad solenoid
Upper limit switch out of
adjustment
Blown fuse
Verify 24 volts at coil when raise
is pushed, if no voltage, trace
wiring back to till her head looking
for voltage on each side of the
connectors until the bad
connection is found.
If voltage is present at the
solenoid and the unit does not
raise, remove the two wires to the
coil and measure the coil
resistance. It should be around
19 ohms. If it’s open, or shorted
replace the solenoid.
Bypass upper limit switch and see
if the unit raises…DO NOT TAKE
IT ALL THE WAY UP… If it does
raise, verify the limit switch is
normally closed and will open
when activated. If the limit switch
is ok, try to adjust the switch
accordingly so that the units raise
height is approximately 7 to 8”
Check fuses above motor
controller
Unit will not raise; motor runs
Lower solenoid stuck on
Check to see if the lowering
switch is stuck on. If it is, remove
the tiller head via 3 screws on
bottom and replace switch, or tap
on switch to see if it can be freed
up.
Unit will not lower
Loose wire; bad coil
Upper limit switch out of
adjustment
Verify 24 volts at coil when lower
is pushed, if no voltage, trace
wiring back to tiller head looking
for voltage on each side of the
connectors until the bad
connection is found.
If voltage is present at the coil
and the unit does not lower,
remove the connector to the coil
and measure the coil resistance.
It should be around 39 ohms. If
it’s open, or shorted replace the
coil.
Loosen hydraulic line at pump to
relieve pressure build up. Re-
adjust limit switch so unit stops at
7 to 8 inches above the ground.
Unit keeps blowing fuses when
the raise button is pressed
Shorted solenoid for motor
raise
Remove the wire to the solenoid
coil on the pump motor. Measure
the resistance, it should be
around 19 ohms. If it is nearly
zero ohms replace the solenoid.