8. TROUBLE SHOOTING
Note: Before service it is necessary to screw two eyebolts into relevant screw-holes
on the basis lest the table lowers accidentally.
Trouble Cause Remedy
Table cannot lift
while motor works
normally
Eyebolt has not been removed
AC Voltage phrases mistake
Electromagnetic dysfunctions
The table is overloaded
Remove eyebolt
Correct AC voltage phrase
electromagnetic valve and repair it
Remove excessive load
Table cannot lift and
motor does not work
Lowering limit switch (if switched)
damaged
Replace limit switch
Table cannot lower
Lowering limit switch or micro-switch
on safety guard damaged
Electromagnetic valve dysfunctions
Safety guard works
Something wrong with electric
circuit board
Replace lowering limit switch
switch or micro-switch.
Check the function of
electromagnetic valve and repair it
Strike the UP button slightly
Replace electric circuit board
Table’s legs go over
limit position (if
existed) while table
lowers
Internal leaking in electromagnetic
valve
Packing damaged in hydraulic
cylinder
Repair electromagnetic valve and
if necessary replace it
Check and replace packing
Table cannot reach
the highest position
Oil not enough
Limit switch damaged
Fill enough oil
Check and repair limit switch. If
necessary, replace it