8. TROUBLE SHOOTING
Note: Before service it is necessary to screw two eyebolts into relevant screw-holes
on the basis lest the table lowers accidentally.
Trouble Cause Remedy
Table cannot lift
while motor works
normally
◇ Eyebolt has not been removed
◇ AC Voltage phrases mistake
◇ Electromagnetic dysfunctions
◇ The table is overloaded
◇ Remove eyebolt
◇ Correct AC voltage phrase
electromagnetic valve and repair it
◇ Remove excessive load
Table cannot lift and
motor does not work
◇ Lowering limit switch (if switched)
damaged
◇ Replace limit switch
Table cannot lower
◇Lowering limit switch or micro-switch
on safety guard damaged
◇ Electromagnetic valve dysfunctions
◇ Safety guard works
◇ Something wrong with electric
circuit board
◇ Replace lowering limit switch
switch or micro-switch.
◇ Check the function of
electromagnetic valve and repair it
◇ Strike the UP button slightly
◇ Replace electric circuit board
Table’s legs go over
limit position (if
existed) while table
lowers
◇ Internal leaking in electromagnetic
valve
◇ Packing damaged in hydraulic
cylinder
◇Repair electromagnetic valve and
if necessary replace it
◇ Check and replace packing
Table cannot reach
the highest position
◇ Oil not enough
◇ Limit switch damaged
◇ Fill enough oil
◇ Check and repair limit switch. If
necessary, replace it