7. SERVICE INSTRUCTIONS
■ Do routine check of fasteners, packing and oil leaking.
■ Do routine check of the function of the lift table.
■ Before service the lift table, make sure to turn off the AC power supply.
■ After service it is necessary to check the function of the lift table again.
■ ONLY a qualified personnel can do service work.
■ Do routine check of the micro-switches on the safety guard.
■ Do routine check of the hydraulic system by listening its noise, touch motor’s surface.
■ Caution: It is necessary to turn off the AC power supply before touch motor’s surface.
■ Pay attention to clear or even replace the oil filter after operating for a long time.
■ Appropriate lubrication is necessary to make the lift table work easily and have a prolonged
service lift.
■ Following table is recommended to service the lift table periodically.
Content
After every 500 hour’
working or every 3
months later
After every 2000
hours working or
every year
Check oil level of oil tank
☆
Check the cleanliness of oil filter
☆
Fasten all the connecting parts again
☆
Check wear and tear of pressure oil pipes
☆
Check hydraulic cylinder
☆
Fix main parts tightly again
☆
Check the function of micro-switches
☆
Check whole working state of the lift table
☆
Lubricate all the joints and pivot points
☆
Check wear and tear of all axial bushes
☆
Replace hydraulic oil for the first time Accumulated working ten hours’
Replace hydraulic oil
☆
Check oil leaking
☆
Remark:
☆