TABLE OF CONTENTS Rev. 6/5/2024 EHLTD MANUAL
TABLE OF CONTENTS Copyright 2024 Vestil Manufacturing Co. Page 30 of 35
Initial inspection.
Prior to use, any new, altered, modified, or repaired scissor lift table must be inspected by a qualified
person. Perform complete DAILY and MONTHLY inspections before returning the lift table to regular use. All
inspected items must be in SATISFACTORY CONDITION.
Daily inspection.
At the beginning of each shift, a designated person shall complete these inspections. Remove the lift
table from service. Repair or replace all affected parts if any of the following is found.
1. Look for:
a. Frayed wires.
b. Oil leaks.
c. Pinched, chafed, worn, or cracking hydraulic hoses.
d. Damage, deformation, or cracks in any structural member or any weld. Give special attention to the
hydraulic cylinder mounting brackets.
e. Loose or missing fasteners.
f. Unusual noise or evidence of binding.
2. Test the function of the upper travel limit switch and the perimeter toe guard. Press the LIFT RAISE button
and hold it. The motor should shut off on its own when the platform reaches its maximum elevation.
Confirm that the cylinder(s) extend smoothly. Press the LIFT LOWER button. The platform should lower
smoothly and evenly.
3. Test the tilting platform upper and lower travel limit switches by cycling the tilting platform all the way
and all the way down. Press the TILT RAISE button and hold it. The motor should turn off on its own when
the tilting platform reaches the maximum inclination (approximately 45° or 90° for EHLTT-H models).
Make sure that the tilting platform cylinder extends smoothly. Lower the tilting platform by pressing the
TILT LOWER button. The motor should activate. Hold the button until the tilting platform is completely
lowered. The motor should turn off when the tilting platform reaches its lower travel limit (fully lowered).
If you have questions about the results of any inspection, contact the TECHNICAL SERVICE AND
REPLACEMENT PARTS DEPARTMENT.
Monthly inspection.
A qualified person must inspect the table for:
1. Oil level. The oil should be 1” to 1-½” below the reservoir fill hole with the platform in the fully lowered
position. Add oil, if necessary. See the ANNUAL INSPECTION section (below) for hydraulic oil specifications.
2. Worn or damaged hydraulic hoses or electrical wires.
3. Wear in the pivot points on the legs.
4. Looseness or wear in the rollers.
5. Integrity of the retaining hardware on all rollers and all pivot point pins.
6. Integrity of the frame anchor bolts, and for cracks in the concrete around them.
7. Proper functioning of hand-operated and/or foot-operated mechanisms.
8. Unusual noises or movement during operation.
9. Condition of all information, safety, and hazard warning labels. All should be clean and clearly legible.
10. Dirt and debris. Clean, sweep, or wipe down as needed.
If you have questions about the results of any inspection, contact the TECHNICAL SERVICE AND
REPLACEMENT PARTS DEPARTMENT.
Annual inspection.
Check the condition of the oil. Change the oil if it darkens, becomes gritty, or turns a milky color
(indicating the presence of water). Replace with an anti-wear hydraulic oil with a viscosity grade of 150 SUS
at 100°F (ISO 32 cSt @ 40°C), such as AW 32, HO 150 or Dexron non-synthetic transmission fluid. You may use
a synthetic transmission fluid if you flush the system with the synthetic fluid before filling the reservoir. 150 SUS
at 100°F (ISO 32 cSt @ 40°C) or Dexron transmission fluid.