Identify all potential hazards and apply relevant safety procedures before
beginning work.
Remove any load and install the maintenance props before beginning any
inspection or service on the lift table.
Only qualified individuals trained to understand mechanical devices, electrical and hydraulic circuits,
and the hazards associated with them, should attempt troubleshooting and repair of this equipment.
Before inspecting or performing maintenance on this lift table:
Remove the load from the platform. Do not attempt to service a loaded lift table.
Fully lower the platform, OR use both maintenance props to support the weight of the platform. To
use the maintenance props, raise the platform to its maximum height. Rotate both props forward so that
their free ends drop into the base frame. Lower the platform until the maintenance props slide up
against the end of the frame.
Disconnect power and follow established lockout/tagout policies as required.
Initial inspection.
Prior to use, any new, altered, modified, or repaired scissor lift table must be inspected by a qualified
person. Perform complete daily and monthly inspections before returning the lift table to regular use. All
inspected items must be in satisfactory condition.
Daily inspection.
At the beginning of every shift, a designated person shall complete these inspections. Remove the lift
table from service and repair or replace any damaged parts if any of the following is found.
1. Look for:
a. Frayed wires.
b. Oil leaks.
c. Pinched, chafed, worn, or cracking hydraulic hoses.
d. Damage, deformation, or cracks in any structural member or any weld. Give special attention to
the hydraulic cylinder mounting brackets.
e. Loose or missing fasteners.
f. Unusual noise or evidence of binding.
g. Wobbly casters, significantly worn casters, casters that do not rotate freely, or caster brakes that
do not work.
2. Test the function of the upper travel limit switch and the perimeter toe guard.
Monthly inspection.
A qualified person must inspect the table for:
1. Adequate oil level. The oil should be 1” to 1-½” below the reservoir fill hole
with the platform in the fully lowered position. See the Annual Inspection
section for the hydraulic oil specification.
2. Worn or damaged hydraulic hoses or electrical wires.
3. Wear in the pivot points on the legs.
4. Looseness or wear in the rollers.
5. Integrity of the retaining hardware on all rollers and all pivot point pins.
6. Proper functioning of any hand- or foot-operated controls/mechanisms.
7. Unusual noises or movement during operation.
8. Condition of all information, safety, and warning labels. Labels should be
undamaged, clean, and clearly legible.
9. Dirt and debris. Clean, sweep, or wipe down as needed.
Annual inspection.
Check the condition of the oil. Change the oil if it darkens, becomes gritty,
or turns a milky color (indicating the presence of water). Replace with an anti-
wear hydraulic oil with a viscosity grade of 150 SUS at 100°F (ISO 32 cSt @ 40°C),
such as AW 32, HO 150 or Dexron non-synthetic transmission fluid. You may use