position with the platform hinged open, therefore THERE IS NO
MECHANICAL LOCKING DEVICE to stop the platform from
lowering. Please see section entitled MAINTENANCE before
attempting any kind of maintenance to the table.
If the table is damaged, deformed or performs incorrectly this
should be reported and usage discontinued. After any major
repair the table must be re-tested according to EN 1570 Annex C.
MAINTENANCE:
N.B. After any major repair the table must be re-tested according
to EN 1570 Annex C.
N.B. The only maintenance that the table usually needs is topping
up of oil and checking for damage.
Maintenance Instructions:
When the table is fully lowered the platform hinges open to allow
access to the hydraulics for topping up the oil. All hinge points
have nylon bearings and all the ball races are sealed, requiring
little maintenance. When topping up the hydraulic oil only fill with
enough oil to allow the table to lift to full height, as overfilling will
cause leakage. The hydraulic oil used in the pump ISO VG22.
The pump and ram can be removed together with the hose for
replacement or service.
Maintenance Periods:
Daily: table should be checked for obvious damage and oil leaks.
Faults should be reported.
Monthly: oil should be checked for serious leaks (oil may escape
from cylinder or from the reservoir, particularly if table is tipped,
tilted or overturned. If in doubt, check with engineer).
Annually: table should be re-tested (see EN 1570 Annex C).
Occasionally: it may be necessary to top up the hydraulic oil (e.g.
after leakage).