REV I | 8/6/19
6
If any safety decal is damaged or not readable, shut down the equipment and do not resume operation
until the decal is replaced. For current pricing and delivery, contact the manufacturer to reorder safety
decals.
3.3 Material Safety
DANGER: Do not process ammable, explosive, toxic, orotherwisehazardousmaterialswithoutrst
performing an appropriate Process Hazard Analysis (PHA).
The manufacturer cannot be an expert in the chemical and biological properties of the innite number
of materials that could be handled by this equipment. This equipment is not designed to safely process
hazardous materials unless additional precautions are taken.
Beforeprocessinganymaterialsthatareorcanreacttobecomeammable,explosive,toxic,orotherwise
hazardous, the user/owner must perform a thorough risk assessment and Process Hazard Analysis of the
entire process, including contingency plans for dealing with processing errors and upset conditions.
3.4 Energy Isolation
DANGER: Electrical enclosures contain hazardous voltage that will result in electrical shock or burn. Turn
oandlockoutequipmentbeforeservicing.
DANGER:Equipmentwithintheelectricalenclosureposesashockandarcashhazardthatmaycause
severe injury or death. Wear proper protective equipment before opening or performing diagnostic
measurementsortestingwhileenergized.Onlyqualiedpersonsshouldopenorworkwithintheelectrical
enclosure.
This equipment must have a lockable isolation/relief device for each energy source. If these device(s)
are not purchased with the equipment, the customer must provide and install a lockable isolation/relief
device for each energy source (in accordance with federal, state, and local codes/standards).
3.4.1 Energy Sources
This equipment incorporates separate energy sources. Proper shutdown and lockout/tag-out
must only be performed by qualied personnel, and must include disabling of all energy
sources including but not limited to the following:
NOTE: Your system may not use all energy sources listed below.
• Electrical:Shutoandlockoutallelectricaldisconnects.Verifyelectricalpowerisin
the o state.
• Pneumatic:Disconnect/shutoairsupply,bleedairfromtheequipment,andlockout.
Verify that energy is relieved/restrained appropriately.
3.4.2 Energy Isolation Method
Before adjusting, servicing, repairing, maintaining, or clearing blockages from this equipment,
complete the procedure below.
1. Review and become familiar with all documentation and schematics. Identify energy
sources and stored energy.
2. Wear appropriate PPE.
3. Fully lower the FLT bucket.
4. Shuto/disconnectthemainairsupply.Allowairtofullybleedfromequipment.
5. Identify and release stored energy as necessary.