Vestel AO-65104 S-T handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 11 van 21
EN - 11
If a cooker hood or cupboard is to be
installed above the appliance, the safety
distance between cooktop and any
cupboard/cooker hood should be as shown
below.
HOB
Minimum
42 cm
Minimum
42 cm
Minimum
65 cm (with
hood)
Minimum 70
cm (without
hood)
The appliance should not be installed directly
above a dishwasher, fridge, freezer, washing
machine or clothes dryer.
If the base of the appliance is accessible
by hand, a barrier made from a suitable
material must be fitted below the base of
the appliance, ensuring that there is no
access to the base of the appliance.
The appliance can be placed close to
other furniture on condition that in the
area where the appliance is set up, the
furniture’s height does not exceed the
height of the cooktop.
Installation of the Hob
The appliance is supplied with an installation
kit including adhesive sealing material, fixing
brackets and screws.
Cut the aperture dimensions as indicated
in the figure. Locate the aperture on the
worktop so that, after the hob is installed,
the following requirements are followed.
B (mm) 646 min. A (mm) 50
T (mm) 523 min. C (mm) 100
H (mm) 44 min. E (mm) 500
C1 (mm) 560 min. F (mm) 10
C2 (mm) 490 G (mm) 20
D (mm) 50 I (mm) 25
J (mm) 5
B
T
C2
A
C
C1
H
F
HOB
G
I
J

Bekijk gratis de handleiding van Vestel AO-65104 S-T, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVestel
ModelAO-65104 S-T
CategorieFornuis
TaalNederlands
Grootte1661 MB