5. Overview
Refer to the illustrations on page 2 of this manual.
1
LCD: indicates the current value and the output voltage of the master.
2
LCD: indicates the current value and the output voltage of the slave.
3
Slave C.V.-adjustment: rotary switch to adjust the output voltage of the slave.
4
Slave C.C.-adjustment: rotary switch to adjust the output current of the slave (to determine the
current-limiting point)
5
Power switch: push button used to activate/deactivate the device. Either the C.V.- or the C.C.-
indicator is lit when the device is activated.
6
C.C.-mode indicator of the slave output or indicator for parallel connection: this indicator is lit when
the slave output is in the C.C.-mode or when the two adjustable outputs are connected in parallel.
7
C.V.-mode indicator of the slave output: this indicator is lit when the slave output is in the C.V.-
mode.
8
Negative binding post of the slave output: the negative pole of the output voltage is connected to the
negative terminal of the load being tested.
9
Earthing connection of the housing: the housing is grounded.
10
Positive binding post of the slave output: the positive pole of the output voltage is connected to the
positive terminal of the load being tested.
11/12
Control switches used to select independent operation, operation in parallel or in series.
13
Negative binding post of the master output: the negative pole of the output voltage is connected to
the negative terminal of the load being tested.
14
Earthing connection of the housing: the housing is grounded.
15
Positive binding post of the master output: the positive pole of the output voltage is connected to the
positive terminal of the load being tested.
16
Master output C.C.-indicator: this indicator is lit when the master output is in the C.C.-mode.
17
Master output C.V.-indicator: this indicator is lit when the master output is in the C.V.-mode.
18
Negative binding post of the fixed 5VDC-output: the negative pole of the output voltage is connected
to the negative terminal of the load being tested.
19
Positive binding post of the fixed 5VDC-output: the positive pole of the output voltage is connected
to the positive terminal of the load being tested.
20
Master output C.C.-adjustment: rotary switch used to adjust the current value of the master output
(adjustment of the current-limiting point).
21
Master output C.V.-adjustment: rotary switch used to adjust the voltage value of the master output.
6. Operation
6.1 Independent use of the two adjustable outputs
Place switches [11] and [12] in the OFF-position.
Proceed as follows when the adjustable outputs are used as C.V.-outputs: put the C.C.-control switches [4]
and [20] in the max. position and use the power switch [5] to activate the device. Install the required DC
output voltage for both master and slave using the rotary switches for C.V.-adjustment [3] and [21]. The
C.V.-indicators [7] and [17] will light.
Proceed as follows when the adjustable outputs are used as C.C.-outputs: Use the power switch [5] to
activate the device. Put the C.V.-control switches [3] and [21] in the max. position and place the C.C.-
control switches [4] and [20] in the min. position. Connect the required load and install the required output
current by means of rotary switches [4] and [20]. The C.V.- mode indicators [7] and [17] will extinguish
and the C.C.-mode indicators [6] and [16] will light.
Bekijk gratis de handleiding van Velleman LABPS23023, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Velleman |
| Model | LABPS23023 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4177 MB |
Caratteristiche Prodotto
| Kleur van het product | Grey, White |
| Gewicht | 7139 g |
| Breedte | 360 mm |
| Diepte | 265 mm |
| Hoogte | 165 mm |