VARI-LITE VL2600 Spot handleiding

55 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 55
uSer manuaL
www.Vari-Lite.com
VL2600 SerieS
25
TAbLE 2. VL2600 PROFILE 16-bIT MODE ENHANCED
DMX
ChaNNeL
ParaMeter DefaULtS raNGe DMX DeSCriPtioN
34
Prism Index/Rot
High Byte
32767
0 - 65535 16-bit control of prism rotation and index.
35
Prism Index/Rot
Low Byte
0 - 32756 Rotate Fast to Slow <<<
32757 - 32780 Rotation STOP
32781 - 65535 Rotate Slow to Fast >>>
36 Frost 0 0-255
Linear control of frost mechanism from out (DMX 0) to full in
(DMX 255)
37 Strobe Speed 0 0 - 255
Controls strobe rate from slowest (DMX 0) to fastest (DMX
255) 0.5hz to 30hz
38 Strobe Control 0 - 255
0 - 255
Control Channel for strobing functions.
Set discrete value of desired e ect, wait >3 seconds, then set
value to 0 (Idle).
0 - 5 Open
6 - 10 Closed
11 - 15 Normal Strobe
16 - 20 Random Strobe
21 - 25 Random Sync
26 - 255 Reserved Values
39
Programmers
Channel
0
0-255
*do not require 3 second Dam rule mode will change once
DMX level I reached
**Set discrete value of desired e ect, wait >3 seconds, then
set value to 0 (Idle). Note some consoles have a delay in
their channel Macro action. For this a time greater then 3
second may be required (6s)
0 - 40 Idle
41 - 80 Linear**
81 -120 S-Curve**
121 -160 Square Curve (Default)**
161 - 180 PL Curve **
181 - 200 For Future Use
201 - 210 Auto CTB ON (Default)**
211 - 220 Auto CTB o **
221 - 225 Edge Tracking OFF**
226 - 230 Edge Tracking ON**
231 - 235 Soft Zoom start ON**
236 - 240 Soft Zoom start OFF**
241 - 245 Dimmer Snap On* (Default)
246 - 250 Dimmer Snap O *
40 Focus Timing 255 0 - 255
Adjustment of fi xture timing to control Pan/Tilt mechanisms.
See Timing Channel Chart in User Manual
41 Optics Timing 255 0 - 255
Adjustment of fi xture timing to control lensing mechanisms.
See Timing Channel Chart in User Manual
42 Color Timing 255 0 - 255
Adjustment of fi xture timing to control lensing mechanisms.
See Timing Channel Chart in User Manual
43 Beam Timing 255 0 - 255
Adjustment of fi xture timing to control beam shaping
mechanisms. See Timing Channel Chart in User Manual
44 Gobo Timing 255 0 - 255
Adjustment of fi xture timing to control gobo mechanisms.
See Timing Channel Chart in User Manual
For future use