Warning deSCription Solution
W22
Supply airow
STEP 1: Unplug the unit. Perform a visual inspection of the supply damper system. Clean
lters, distribution registers and outside supply hood. Inspect ducting to ensure it is not
squeezed or bent. Plug the unit.
If STEP 1 did not x the problem, perform STEP 2: Remove ducting of the supply path. On the
LCD screen, select MAX to check if the unit is able to reach the selected ow. If so, review the
ducting path.
If STEP 2 did not x the problem, perform STEP 3: On the LCD screen, select the MIN and
MAX ow setting values then reset the unit. MAX ow value will display on the LCD screen. If
MAX ow is above desired MAX ow, set MAX and MIN ows.
If STEP 3 did not x the problem, perform STEP 4: Replace the supply blower and repeat
STEP 3.
If STEP 4 did not x the problem, perform STEP 5: Replace the electronic assembly.
W32
Exhaust airow
STEP 1: Unplug the unit. Perform a visual inspection of the exhaust damper system. Clean
lters, distribution registers and outside exhaust hood. Make sure no non-return damper
is installed in exhaust hood since it can freeze in winter. Inspect ducting to ensure it is not
squeezed or bent. Plug the unit.
If STEP 1 did not x the problem, perform STEP 2: Remove ducting of the supply path. On the
LCD screen, select MAX to check if the unit is able to reach the selected ow. If so, review the
ducting path.
If STEP 2 did not x the problem, perform STEP 3: On the LCD screen, select the MIN and
MAX ow setting values then reset the unit. MAX ow value will display on the LCD screen. If
MAX ow is above desired MAX ow, set MAX and MIN ows.
If STEP 3 did not x the problem, perform STEP 4: Replace the exhaust blower and repeat
STEP 3.
If STEP 4 did not x the problem, perform STEP 5: Replace the electronic assembly.
W52
Initial setting
incomplete
STEP 1: Press + or - to access the selection menu.
STEP 2: Complete conguration. (Refer to section 5 for more details).
W61
Protection mode
electronics
overheating
The unit is currently in protection mode. The power transmitted to the motor is deliberately
reduced to decrease electronics temperature. The unit will exit this mode by itself once
conditions are back to normal. It is normal to observe reduction in airows during this period.
This condition should appear only when the unit is set in high speed and located in a warmer
environment, for example over 30°C (86°F).
8. INSTALLER’S TROUBLESHOOTING (Contd)
Make sure that no piece of mineral wool will enter in the unit during installation. Otherwise, this could reduce
airow and generate vibrations and noise in the unit.
CAUTION
NOTE: 210 and 230 CFM models have a cooling fan in electrical box that can start if ambient temperature near the unit is
over 40°C (104°F).
180 CFM ERV Models
The unit will reduce airow by 30 CFM if the max airow during auto-balancing procedure is 130 CFM or less to prevent
ERV core membrane deformation due to very high static pressure (over 1.3 in. w.g.).
All 180 CFM Models
Error E22 or E32 will display if the maximum airow is 90 CFM or less during the auto-balancing procedure (the unit
will attempt to execute auto-balancing procedure 3 times before displaying an error). Static pressure of ducting shall be
reduced to allow good operation of the unit.
210 CFM ERV Models
The unit will reduce airow by 30 CFM if the max airow during auto-balancing procedure is 160 CFM or less to prevent
ERV core membrane deformation due to very high static pressure (over 1.3 in. w.g.).
All 210 and 230 CFM Models
Error E22 or E32 will display if the maximum airow is 120 CFM or less during the auto-balancing procedure (the unit
will attempt to execute auto-balancing procedure 3 times before displaying an error). Static pressure of ducting shall be
reduced to allow good operation of the unit.
8.1 elecTronic proTecTion To prevenT AbnormAl HiGH sTATic pressure

Bekijk gratis de handleiding van VänEE V180H75RT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVänEE
ModelV180H75RT
CategorieAirco
TaalNederlands
Grootte8909 MB