LIQUID VACUUM OPERATION
6
2
1
5
3
6
5
7
4
LIQUID VACUUMING
WARNING:
BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION
ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”. DO NOT VACUUM IN AREAS WITH
FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE
GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN, OR
GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR DUST,
DO NOT VACUUM TOXIC MATERIALS.
WARNING:
DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE
SURE THE PLUG IS DISCONNECTED BEFORE CHANGING THE FILTERS.
1. Verify that the power cord is disconnected from the outlet. Make sure that the collection tank is
clean and free of dust and dirt (Fig. 1).
2. Remove the cartridge lter, then carefully install the foam wet lter over the lter cage and
place the power head back on the collection tank (Fig. 2). For foam wet lter installation
instructions, see page 14.
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
OPERATING INSTRUCTIONS: WET VACUUMING
3. Push the required attachment onto the free end of the hose or extension wand (Fig. 3).
4. Verify that the on/off switch is in the ‘O’ OFF position before plugging the power cord into the
power outlet. Plug the power cord into the outlet (Fig. 4 & 5).
5. Turn the motor on by ipping the switch to the ‘I’ ON position (Fig. 6).
6. Once you have completed vacuuming, ip the on/off switch to the ‘O’ OFF position and unplug
the power cord from the outlet.
7. After use, empty the collection tank, clean, and dry the inside and outside of the collection tank
(Fig. 7).
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely
in the liquid; leave a gap at the tip of the nozzle opening to allow air inow. The machine is tted
with a oat valve that stops the suction action when the collection tank reaches its maximum
capacity. You will notice an increase in motor speed. When this happens, turn off the machine,
disconnect from power supply, and drain the liquid. After wet vacuuming, turn the machine off and
remove plug from power supply. Empty the collection tank, clean and dry the inside and outside
before storage.
REMEMBER! The foam wet lter must be removed after wet vacuuming and the cartridge lter
must be installed before dry vacuuming again.