2.1 Location
WARNING
Leaking coolant and oil!
Fire. The coolant contained in the appliance is eco-friendly,
but also flammable. The oil contained in the appliance
is flammable. Escaping coolant and oil can ignite if the
concentration is high enough and in contact with an
external heat source.
u
Do not damage the pipelines of the coolant circuit and
the compressor.
-
If the appliance is installed in a very humid environment,
condensation can build up on the outside of the unit.
Always ensure good airlow and ventilation in the installa‐
tion location.
-
The more refrigerant there is in the appliance, the larger
the space that it is installed in must be. If the space is
too small, any leak may create a flammable mixture of
gas and air. For every 8 g of refrigerant, the installation
space must be at least 1 m
3
. Information regarding the
coolant can be found on the serial tag inside the appli‐
ance.
2.1.1 Supporting floor
-
The floor of the installation site must be horizontal and
even.
-
If you are installing the unit in a cabinet standing on an
uneven floor: level the cabinet.
2.1.2 Positioning
-
Do not install appliance in direct sunlight or next to an
oven, radiator or similar.
-
Only fit the appliance into solid kitchen units.
Note
Please contact Customer Services to acquire a kit to limit
the door opening angle to 90° for appliances with soft close
mechanisms.
2.2 Installing multiple appliances
NOTICE
Risk of damage due to condensate!
u
Do not install the appliance directly alongside a further
refrigerator/freezer.
NOTICE
Risk of damage due to condensation!
u
Do not install the appliance directly above another refrig‐
erator or freezer.
These appliances are designed for a variety of installation
options. Combine appliances only if the appliance is suit‐
able. The following table shows the installation options by
model:
Installation
option
Model
Single All models
Side-by-side
(SBS)
Model names starting with S....
Installation
option
Model
Stacked Models up to a maximum recess height of
880 mm and with a heated cover can be
“stacked”.
Upper appliance: up to a maximum recess
height of 140 mm
Fig. 1
Build each appliance into a separate recess.
2.3 Mains connection
WARNING
Danger of fire due to incorrect positioning!
If the mains cable or plug touches the back of the appli‐
ance, the vibration can damage the mains cable or the plug
resulting in a short circuit.
u
Make sure the mains cable is not trapped under the appli‐
ance when you position the appliance.
u
Stand the appliance so that it is not touched by connec‐
tors or main cables.
u
Do not connect any appliances to sockets in the area of
the back of the appliance.
u
Do not place and operate multi-sockets/power distribu‐
tors and other electronic devices (such as halogen trans‐
formers) at the back of the appliances.
Installation conditions
52 * Depending on model and options