5 Product Introduction
9
The definition of the VT-16076W,VT-16076B operation panel is shown as folloaws.
Table 5-1 Operation Panel Interface Definition
Items
Remark
SOC
State of charge
RUN/ALM
To indicate the running or alarm status of battery
J5
J5 is used for communication between batteries.
J7
J7 is used for debugging BMS.
J6
J6 is used for communication with inverter .
PWR
Indicates the switching status of battery and prompts whether
the battery device is on or off
COM
When alarms and protection occur, a closed loop is formed here
BMS SWITCH
Short time contact boot,Prolonged contact shutdown
ADS Dialer
Parallel address dip switch
ANT
Receive blue tooth signal
The SOC indicator used to identify the current capacity status of the battery.
The number of blinking indicators corresponds to different remaining capacity. The
specific meaning is shown as follows.
Table 5-2 The SOC Indicator Definition
No.
Indicator Light
Remark
1
0% ≤ SOC ≤ 16%
2
17% < SOC ≤ 32%
3
33% < SOC ≤ 49%
4
50% < SOC ≤ 65%
5
66%< SOC ≤ 83%
6
84%< SOC ≤ 100%