8 Maintenance
Warning!
Improper decommissioning may cause damage to the equipment and/or
battery inverter.
Before maintenance, ensure that OHS-100 is decommissioned according to relevant provisions.
Note: All maintenance work shall comply with local applicable regulations and standards.
The USB-CAN port of OHS has the functions of upgrading firmware and recording battery
data, which can be used as an auxiliary tool.
To ensure safe operation, all plug connections must be checked. If necessary, relevant
operators shall press them back into place at least once a year.
The following inspection or maintenance must be carried out once a year:
• General visual inspection
• Check all tightened electrical connections. Check the tightening torque according to
the values in the following table. Loose connections must be retightened to the
specified torque.
Connection mode
Tightening torque
high-voltage BMS box grounding
4.5Nm
Fixing the lug of the high-voltage BMS box
1.2Nm
Fixing the lug of the battery module
1.2Nm
• Using the monitoring software, check whether the SoC, SoH, battery voltage and
temperature of the battery module are abnormal.
• Shut down and restart OHS-100 once a year.
Note: If the system is installed in a polluted environment, maintenance and cleaning
must be carried out at short intervals.
Note: Clean the battery rack with a dry-cleaning cloth. Ensure that no moisture comes
into contact with the battery connections. Do not use solvents.