7 Parallel Connection
25
If you will install more than 2pcs batteries (No more than 15pcs) , you will have
the following two system wiring options.
Option 1. Connect all batteries to the bus bar.
NOTE
For this wiring solution, you will need to prepare bus bars and power cables to
connect the bus bars to the inverter in addition. You can either purchase them
independently or obtain them from Vtac or the supplier.
In this wiring solution, the Max. output current of the system will be 100A* the
quantity of batteries in parallel.
Battery Quantity of Parallel
Cable Kit
3 PCS
Master Cable Kit * 3 set
...
...
N PCS (4≤N<15)
Master Cable Kit * N set (4≤N<15)
...
...
15 PCS
Master Cable Kit * 15 set