44
© 2007 directed electronics
Full trigger response
3300
or 60 seconds: This determines how
long the full triggered sequence lasts. Some states have laws
regulating how long a security system can sound before it is
considered a nuisance. If your installer is programming the
security system with the Ungo ProSecurity Programmer, the
full triggered response can be programmed for any duration
ranging from 1 to 180 seconds.
Automatic Engine Disable (AED) on or
ooffff
. The purpose of
this feature is to protect the vehicle from being stolen at all
times, regardless of whether or not the alarm is armed. If
AED is programmed on, the starter of the vehicle will be
disabled 30 seconds after the ignition is turned off. Once the
key is turned off, the LED will flash slowly (one-half its
normal armed rate) to indicate the AED arming cycle.
Thirty seconds later, the starter will be disabled. To start the
car, it will be necessary to disarm the system with the trans-
mitter. It is also possible to disarm the AED feature by
turning the ignition key to the RUN position and pressing
the Valet
®
button the programmed number of times. AED
is also disabled when the system is in Valet
®
mode.
note: When the system passively arms after one hour, the
entry point that has been left open, and anything con-
nected to the same zone, is bypassed and cannot trigger
the system. However, the remaining inputs to the system
are fully operational.