UNGO ProSecurity S670 handleiding

39 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 39
18
© 2006 directed electronics, inc.
RReemmoottee CCoonnttrrooll NNoottiiffiiccaattiioonn
- Ten quick beeps (or vibra-
tions).
RReemmoottee CCoonnttrrooll LLCCDD
- The full trigger alert icon (28) will
dimly illuminate for two seconds
The transceiver will enter Page Recognition Mode and
operate alarm page alerts.
triggered response description
A Triggered Response can be activated by any of the triggers
listed below and consists of an alarm page along with the
response described for each trigger. The Triggered Response
duration is 30 seconds.
SSeennssoorr TTrriiggggeerr
- Heavy impacts to the vehicle will instantly
sound the siren and flash the lights for the programmed
duration and report Zone 2.
DDoooorr TTrriiggggeerr
- If a door is opened the siren will chirp for
three seconds, then the siren will sound and the lights will
flash for the programmed duration and report Zone 3. The
three seconds allow the user time to disarm the system with
a minimum of noise should a door be opened inadvertently
while the system is armed.
HHoooodd TTrriiggggeerr
- Opening the hood (if connected) will sound
the siren, flash the lights for the programmed duration, and
report Zone 1.
note: Icons 13 and 14 represent alarm system zone
inputs. For more information about icons and the zones
they represent refer to the
Standard Remote
Configurations
section.