Ulsonix AIRCLEAN 600P handleiding
Handleiding
Je bekijkt pagina 6 van 21

16.12.2021
16.12.2021
1110
E. Back cover
F. 3-in-1 lter (pre-lter, carbon lter, catalytic lter)
G. Ceramic ozone plate
H. UV lamp
I. Ozone plate placement
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. Keep the product away from hot surfaces. The
device should always be used when positioned on an
even, stable, clean, reproof and dry surface, and be out
of the reach of children and persons with limited mental
and sensory functions. Position the device such that you
always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
1. Fan
2. Remote control
3. Display
3
2
1
4
5
10
11
6
7
8
9
4. „POWER” button
5. „REMIDER RESET” button
6. „AWAY MODE” button
7. „NORMAL/HIGH” button
8. Button increasing the air-ow speed (FAN )
9. Button decreasing the air-ow speed (FAN )
10. Button increasing the ozonation level (STERILZE )
11. Button decreasing the ozonation level (STERILZE
)
12. Power switch
13. Connecting the power cord
14. UV lamp
15. Back cover
16. 3-in-1 lter (pre-lter, carbon lter, catalytic lter)
17. Ceramic ozone plate
12
13
14
15
16
17
B
A
C
D
A. „ON/OFF” button
B. „OZONE” button
C. Timer
D. Fan
I
H
G
F
E
ASSEMBLING THE DEVICE
The correct installation of the lter is shown in the gure
below.
3.3. DEVICE USE
AIRCLEAN 600P
1. Connect the device to the power supply.
2. Turn the device on with the power switch. Then press
the "POWER" button.
3. Set the appropriate parameters:
a) Mode selection:
» "NORMAL" mode - the UV lamp and catalytic
lter are turned on. A blue light on the front of
the device will switch on. CAUTION! You must not
look directly at the blue light.
» "HIGH" mode - UV lamp and ozonation
("STERILZE") will be turned on.
b) Adjustment of parameters
• SETTING THE OZONATION LEVEL
Adjust using the "STERILZE △" and "STERILZE ▽"
buttons. It is recommended to select the ozonation
level depending on the area (12 levels): 1 m
2
- 46 m
2
- 70 m
2
- 93 m
2
- 116 m
2
- 139 m
2
- 163 m
2
- 186 m
2
- 209 m
2
- 232 m
2
- 255 m
2
- 279 m
2
>.
• SETTING THE AIR-FLOW SPEED
Adjust with the "Fan △" or "Fan ▽" buttons (5 levels).
• OZONATION WITH A TIMER
In order to activate ozonation in time mode, press the
"AWAY MODE" button and then set the time (1, 2, 4, 6,
8, 10 or 12 hours) of the device operation. The device
turns o automatically.
4. After use, switch the device o and disconnect from
the power supply.
CAUTION! The icon informs about changing the
lter by "blinking". After replacing the lter, reset the
lter condition by pressing and holding the "REMIDER
RESET" button on the panel for 10 seconds until the
icon disappears.
CAUTION! The device can be controlled using the
control panel or the remote control. The remote
control has additional functions: "APCO" - turns the
UV lamp on/o and the "Plasma" button - turns the
ion functions on/o.
AIRCLEAN 600B
1. Connect the device to the power supply.
2. Turn the device on with the power switch.
3. Press the "ON/OFF" button (After turning the device
on, the fan, ionizer, UV lamp and ozonator at level
I will turn on automatically).
4. Enter the settings:
• The timer can be set to 2, 4, 6 or 8 hours.
• The ozonator intensity can be adjusted with the
"OZONE" button (4 levels). The ozonation function
will automatically turn o after one hour if the timer is
not set.
CAUTION: The ionizer works regardless of the
ozonator.
5. After use, switch the device o and disconnect from
the power supply.
NOTE! Upon completion of treatment ventilate the
room for 15 to 30 minutes. Do not enter the room
for at least 2 hours after completion of the ozone
treatment.
NOTE ! Ozone is an irritant gas, it may cause damage
to biological membranes through radical reactions
with their constituents. If the characteristic ozone
smell is still present in the room which was treated
with ozone, rst make sure that the device is switched
o then leave the room and/or ventilate it.
3.3.1. RECOMMENDED WORKING TIME
Recommended working time [min] depending on the
room volume [m
3
]
m
3
50 100 150 200 300
min 60 120 180 240 360
NOTE! Do not exceed the “Recommended operation
duration” as indicated in the above tables.
3.4. CLEANING AND MAINTENANCE
a) Always unplug the device before cleaning it.
b) Use only non-corrosive cleaners to clean the surface.
c) After cleaning the device, all parts should be dried
completely before using it again.
d) Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
e) Do not spray the device with a water jet or submerge
it in water.
f) Do not allow water to get inside the device through
vents in the housing of the device.
g) The device must be regularly inspected to check its
technical eciency and spot any damage.
h) Use a soft, damp cloth for cleaning.
i) Do not use sharp and/or metal objects for cleaning
(e.g. a wire brush or a metal spatula) because they
may damage the surface material of the appliance.
j) When the purier no longer produces enough ozone,
clean the ozone plate of dust with a soft cloth. It is
recommended to replace the ozone plate every 6
months.
DISPOSING OF USED DEVICES
Do not dispose of this device in municipal waste systems.
Hand it over to an electric and electrical device recycling
and collection point. Check the symbol on the product,
instruction manual and packaging. The plastics used to
construct the device can be recycled in accordance with their
markings. By choosing to recycle you are making a signicant
contribution to the protection of our environment. Contact
local authorities for information on your local recycling
facility.
3.1. DEVICE DESCRIPTION
AIRCLEAN 600P
AIRCLEAN 600B
ENEN
Bekijk gratis de handleiding van Ulsonix AIRCLEAN 600P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Ulsonix |
| Model | AIRCLEAN 600P |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 5934 MB |