Cleaning of sewage
1. When the sewage reaches the maximum water level, stop working and turn o the
power. Remove the sewage bucket in the direction of arrow.
2. Open the upper cover of the sewage bucket and pour away the sewage. Do not tilt
or shake the sewage bucket when carrying it: otherwise, the sewage will outow easily.
3. Clean the bucket, upper cover and sealing strip. Clean the sewage bucket in time
after use, so as not to cause bacteria and smell.
4. Install the sealing ring, cover, and fasten the sewage bucket.
5. Buckle the sewage bucket into the body. Lock the sewage bucket without shaking;
otherwise, it will easily leak and aect the cleaning.
6. When the water exceeds the maximum water level, the machine will automatic stop
and the red LED will ash to remind cleaning the tank. Please stop using, pour away the
waste water and restart the machine.
Status Fault cause analysis Handling
The machine does not
work after the switch is
turned on
• The plug is not properly con-
nected and loose, resulting in
poor contact.
• The internal line or power cord
is broken.
• The machine set overheats, and
the protective device operates
• Turn o the power and plug it
again.
• Call the repair telephone.
• Refer to the instructions for
protective device.
When the watering bu-
tton is pressed, there is
no water or little water
• The nozzle is blocked.
• The handle or pump is damaged.
• Remove the water sucker and
rinse the nozzle with clean water.
• Call the repair telephone.
There is no dust collec-
tion, or the suction is
very weak
• The power switch is not turned
on. The sewage bucket is full, cau-
sing the oating ball to work.
• The hose is abnormal.
• The sewage bucket is not insta-
lled in place.
• The inlet air sponge is blocked
• Turn on the power switch.
• Clean up the sewage and use it
again. Check the hose for cracks,
breaks, and clogs.
• Install the sewage bucket
properly. Clean or replace the
sponge.
CONSUMABLES, FAULT AND HANDLING
The consumables can be removed and replaced when damaged or lost. Be sure to
install and use:
Seal ring for upper cover
Inlet air sponge