MNL- C2-6204-V3.00    55 
The CHA byte indicates the macro p57-we are programming / reading / running.  Macro 1 to 5 are CHA 0..4, 
CHA=5 is restore, CHA 6..7 are Macros 6..7. 
Macro Restore (CHA=5) is read only, the units restore state is set by sending the Store command (0C8). 
Reading a previously stored Macro  
In order to read a macro the following commands must be sent in this specific order – no other 
commands should be sent between these messages.  The CHA in these cases relate not to the source but 
to the macro p57-we are reading. 
Packet sent 
Packet returned 
SOP 
CMD 
CHA 
WIN 
OUT 
FUN 
PAY 
CS 
EOP 
SOP 
CMD 
CHA 
WIN 
OUT 
FUN 
PAY 
CS 
EOP 
Read number of items currently stored in Preset 2              Returned packet indicates 4 items available to read 
F 
84 
01 
42 
00 
F4 
- 
BB 
CR 
F 
44 
01 
42 
00 
F4 
00002 
FC 
CR 
Read the Function for the first item in the preset / macro 
Payload is the Function stored – 86 = Zoom 
F 
84 
01 
42 
00 
F3 
- 
BA 
CR 
F 
44 
01 
42 
00 
F3 
000086 
?80 
CR 
Read the Data for the first item in the preset / macro 
Payload is the data for the function – 100% 
F 
84 
01 
42 
00 
F2 
- 
B9 
CR 
F 
44 
01 
42 
00 
F2 
000064 
5D 
CR 
Read the Function for the second item in the preset / 
macro 
Payload is the Function stored – 87 = Shrink 
F 
84 
01 
42 
00 
F3 
- 
BA 
CR 
F 
44 
01 
42 
00 
F3 
000087 
81 
CR 
Read the Data for the second item in the preset / macro 
Payload is the data for the function – 100% 
F 
84 
01 
42 
00 
F2 
- 
B9 
CR 
F 
44 
01 
42 
00 
F2 
000064 
5D 
CR 
The above example shows the read for all the items within macro 0.  The first command reads the 
number of items available in the macro and resets the read address. Then the following items read the 
function and then the data for each of the items in the preset/macro.  Following a read of the data for a 
macro internally the next item in the macro is selected for reading so it is not possible to read the same 
item twice without first re-reading the number of items in the macro. 
Writing to a macro 
Menu text 
CHA 
FUNC 
(Hex) 
Range of adjustment (decimal) 
Macro 
Run macro 
0..7 
F1 
0..1 = Run, Erase macro 
Number of items within macro 
0..7 
F4 
Read Only 
Function to adjust 
0..7 
F2 
0..4095 
Value 
0..7 
F3 
Value for Function 