Handleiding
Je bekijkt pagina 11 van 46

7-2. Electrical Inspection
IS RATED VOLTAGE SUPPLIED TO THE POWER PLUG
PROPERLY? [AC 120V]
IS RATED VOLTAGE SUPPLIED TO RATED VOLTAGE
LINE [1] AND [2] PROPERLY? [AC 120V]
IS RATED VOLTAGE SUPPLIED TO SMPS RATED
VOLTAGE LINE [3] AND [4] PROPERLY? [AC 120V]
IS DC VOLTAGE 24V SUPPLIED TO SMPS OUTPUT LINE
[5] AND [6] PROPERLY? [DC 24V]
IS DC VOLTAGE 24V SUPPLIED TO SMPS OUTPUT LINE
[6] AND SWITCH OUTPUT LINE [7] PROPERLY?
[DC
RATED VOLTAGE SUPPLY DEFECT
[AC 120V]
JUNCTION AND POWER PLUG
WIRING JUNCTION DEFECT
SMPS DEFECT
SWITCH AND JUNCTION DEFECT
IS DC VOLTAGE 24V SUPPLIED TO LED LINE [5]
LED DEFECT
YES
YES
YES
NO
YES
YES
NO
YES
NO
NO
NO
NO
IS RATED VOLTAGE 120V SUPPLIED TO RATED
THERMOSTAT DEFECT
YES
NO
IS RATED VOLTAGE 120V SUPPLIED TO FAN
FAN MOTOR DEFECT
YES
NO
IS RATED VOLTAGE 120V SUPPLIED TO COMP
COMP DEFECT
YES
NO
IS RATED VOLTAGE 120V SUPPLIED TO POWER
POWER RELAY DEFECT
YES
NO
IS RATED VOLTAGE 120V SUPPLIED TO FAN
FAN MOTOR DEFECT
YES
NO
IS RATED VOLTAGE 120V SUPPLIED TO COMP
COMP DEFECT
YES
NO
Electrical Inspection Completion