Handleiding
Je bekijkt pagina 11 van 20

11
LEVELING THE OPEN DISPLAY MERCHANDISER & BAKERY CASE
Four leveling legs are provided to level your Merchandiser. Use a leveler to ensure
the unit is evenly leveled on all four corners. If the unit is not leveled correctly, excess
water buildup will not drain properly. If you do not wish to use the levelers, they can
be turned inwards.
TBA- Series
MODEL
V/Hz
REFRIGERANT
HP
AMPS
WEIGHT (lbs)
TBA37-50N-W(B)
115V/60Hz
R-290
7/8
10.5
450
TBP49-50N-W(B)
115V/60Hz
R-290
3/4 x 2
15.7 5
50
DAMAGE INSPECTION
Prior to installation, the customer must check for damages with the freight company
before the unit is accepted.
1. If the crate is damaged, make sure to note the damage on the Bill of Lading
prior to signing the delivery off.
2. Concealed damage must be reported within 5 days of receiving the unit. Bill
of Lading must be faxed to the Claims department. Pictures of both unit and
crating may be requested.
LOCATION OF OPEN DISPLAY MERCHANDISER & BAKERY CASE
Open Display Merchandisers & Bakery Cases are designed to be in an area that is
ambient 75 degrees Fahrenheit (dry bulb) or colder with 55 percent relative humidity.
If the installed unit is in a warm ambient area, it may not be as effective. Position the
unit at its final location before removing the shipping skid. There are four bolts at the
bottom of the unit that secure the shipping skid. Remove all four bolts to remove the
skid. Allow three inches of space from the wall to the back of the merchandiser.
Condenser is located to the front. Do NOT block inlet.
TBA Series
SPECIFICATIONS
Bekijk gratis de handleiding van Turbo Air TBA49-50N-W, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Turbo Air |
Model | TBA49-50N-W |
Categorie | Koelkast |
Taal | Nederlands |
Grootte | 2527 MB |