BASIC OPERATION
CONTROLLER DISPLAY
SET POINT CHANGE
U
P
PROGRAMMING OF SET POINT (“Set point” - Cabinet internal temperature setting)
Our refrigerator compressors will turn on when the return air temperature reaches
40°F and above. The compressor will also turn off once the return air temperature
reaches 34°F.
To change the Set Point, please follow the steps below:
1. Hold the “P” button firmly for two (2) seconds and release. The display will show
“SP” and will indicate the current set value and will be in Setting mode.
2. To change the Set Point, press the “UP” button to increase the Set Point, or
“DOWN” to decrease the Set Point.
3. Press the “P” button to save the Set Point value and exit out of Setting Mode.
1. Plug unit into the correct outlet. The power switch is located on the back side of the
unit. Flip the power switch ON. Display panel should light up if these steps are
followed correctly.
2. The default temperature (“Set Point”) is set to 37°F (for Refrigerators).
3. The compressor is set to automatically cycle based on the cabinet temperature, and
is controlled by the main PCB (“Controller”).
4. The defrost cycle is set to automatically cycle and is controlled by the Controller, as
well as the door switch.
Inner Temperature Display
Defrost Light
Evaporator
Fan Light
Compressor
Light
1. CLEANING THE INTERIOR AND EXTERIOR
- The interior and exterior of the unit can be cleaned using warm water and soap.
- Do not use an abrasive cleaner because it will scratch the surface.
2. CLEANING THE CONDENSER COIL
- To maintain proper refrigeration performance, the Condenser coil must be free of
dust, dirt, and grease. This will require periodic cleaning. Condenser coil should
be cleaned at least every three months (90days) or as needed.
- To clean the condenser, unplug the power cord. Condenser can be cleaned with
vacuum, brush, or CO2 (high pressure air).
3. CLEAN THE DRAIN PAN
- Periodically, empty the drain pan which is located under the unit.
-
When reinstalling the Drain Pan, make sure the drain hose is placed back into the pan.
4. CHECK AFTER CLEANING
1) Check the unit again for safety.
2) Plug unit back in and turn on power switch.
3) Check that the unit is operating properly.
14
CLEANING
CAUTION
Before cleaning, unplug the unit and disconnect the power.
Wipe and clean the inside and outside of appliance with a damp cloth.
1. POWER CORD
- Be sure the power cord is connected to the proper voltage.
- A protected circuit of the correct voltage and amperage must run for connection of
the line cord.
- Turn ‘off’ the power switch before disconnected the power cord, whenever
performing maintenance functions or cleaning the refrigerated cabinet.
- Compressor warranties are void if compressor burns out due to low voltage.
2. RESTARTING
- If disconnected, wait 5 minutes before restarting.
3. POSITIONING GOODS
- Do not obstruct the air inlet which is located at the back inside of the unit.
NOTE: For a self-cleaning condenser equipped model, condenser cleaning is not
required. However, it is recommended to blow the condenser coil out with Nitrogen
once or twice a year. Note that the condenser cleaner may not remove grease.