About Your Appliance & Installation Requirements (cont.)
Wire gauge chart (115V)
115
Volts
Distance in Feet to Center of Load
AMPS 20 30 40 50 60 70 80 90 100 120 140 160
2 14 14 14 14 14 14 14 14 14 14 14 14
3 14 14 14 14 14 14 14 14 14 14 14 12
4 14 14 14 14 14 14 14 14 14 12 12 12
14 14 14 14 14 14 14 12 12 12 10 10
6 14 14 14 14 14 14 12 12 12 10 10 10
7 14 14 14 14 14 12 12 12 10 10 10 8
8 14 14 14 14 12 12 12 10 10 10 8 8
9 14 14 14 12 12 12 10 10 10 8 8 8
10 14 14 14 12 12 10 10 10 10 8 8 8
12 14 14 12 12 10 10 10 8 8 8 8 6
14 12 12 12 10 10 10 8 8 8 6 6 6
16 12 12 12 10 10 8 8 8 8 6 6 6
18 12 12 10 10 8 8 8 8 8 8 8 5
20 12 12 10 10 8 8 8 6 6 6 5 5
25 10 10 10 8 8 6 6 6 6 5 4 4
30 10 10 8 8 6 6 6 6 5 4 4 3
Wire gauge chart (230V)
230
Volts
Distance in Feet to Center of Load
AMPS 20 30 40 50 60 70 80 90 100 120 140 160
5 14 14 14 14 14 14 14 14 14 14 14 14
6 14 14 14 14 14 14 14 14 14 14 14 12
7 14 14 14 14 14 14 14 14 14 14 12 12
8 14 14 14 14 14 14 14 14 14 12 12 12
9 14 14 14 14 14 14 14 14 12 12 12 10
10 14 14 14 14 14 14 14 12 12 12 10 10
12 14 14 14 14 14 14 12 12 12 10 10 10
14 12 12 12 12 12 12 12 12 10 10 10 8
16 12 12 12 12 12 12 12 10 10 10 8 8
18 12 12 12 12 12 12 10 10 10 8 8 8
20 12 12 12 12 10 10 10 10 10 8 8 8
25 10 10 10 10 10 10 10 10 8 8 6 6
30 10 10 10 10 10 10 8 8 8 6 6 6
Fig. 1. Fully insert the power cord into
the receptacle.
Fig. 2. Push the red button to remove
the plug.
NEMA Plug Configurations
60 HZ USE ONLY!
TRUE uses these types of NEMA plugs shown. If you DO NOT have
the proper outlet, have a licensed electrician verify and install the
correct power source.
International (IEC) Plugs Only
International appliances may be supplied with a power cord that
will require installation. Install this cord before connecting the
appliance to a power source.
NOTICE ›
International plug configurations will vary by country
and voltage.
Installation
Fully seat the power cord into the appliance receptacle until it
locks in position. See fig. 1.
Removal
Depress the red button. See fig. 2.
Electrical Installation & Safety
Electrical Requirements
USER ACTION!
Find a copy of the wiring diagram with our serial
number lookup at
truemfg.com/support/serial-number-lookup.
DANGER!
• Never use an extension cord! An extension
cord is any component that adds length to the
OEM power cord when connecting the cord to
a power source.
• Never use an adapter plug! An adapter plug
alters the OEM plug configuration when
connecting the plug to a power source.
• Always use the correct outlet. See "NEMA
Plug Configurations" below.