True T-49G-4-HC handleiding

31 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 31
13
TRUE
traditional reach-ins
www.truemfg.com
1
INSTALLATION INSTRUCTIONS
DANFOSS TEMPERATURE CONTROL ADJUSTMENT
FOR HIGH ALTITUDE APPLICATIONS:
REQUIRED TOOLS:
Allen Wrench (5/64")
Torx Screw (T-7)
TERMS:
Cut-out - Temperature sensed by the controller that shuts the
compressor off.
Cut-in - Temperature sensed by the controller that turns the
compressor on.
WHEN TO MAKE AN ADJUSTMENT TO A MECHANICAL TEMPERATURE CONTROL
OPERATION INSTRUCTIONS:
REQUIRED TOOLS:
Jewelers Screw Driver (Small Screw Driver)
GE CONTROL INSTRUCTIONS:
The scale to the right may be used as a guide for measuring
degrees of rotation required for altitude correction. See Figure 1.
The arrows indicate direction of screw rotation. Turn calibration
screw clockwise to obtain warmer operating temperatures.
NOTE: Each 1/4 turn of the calibration screw is equal to
approximately 2 degrees F. Do not make more than 3/4 turn.
After making adjustment, measure temperature during three
cycles before adjusting again.
NOTE: Only adjust the screw
(small flathead) on the face of
the control (next to the cam).
See Figure 3.
Follow the Altitude Correction
Table to the right.
W
A
R
M
E
R
C
O
L
D
E
R
60
30
45
40
35
50
55
15
20
25
10
5
We advise to make a mechanical temperature control adjustment only for a high altitude location.
Compressor
Terminals
Ground
Terminal
To adjust the temperature control
take the control knob off to view the
cut-in screw. (See Photo Above)
Front of Temperature Control
Calibration
Screw
1 2
3
Cut-out Adjustment
Screw Allen (5/64" or 2 mm.)
Cut-in Adjustment
Screw Torx (T-7)
Compressor
Connection
ALTITUDE CORRECTION TABLE:
CALIBRATION SCREW ADJUSTS
BOTH CUT-IN AND CUT-OUT
Altitude (Feet)
2000
3000
4000
5000
6000
7000
8000
9000
10,000
Clockwise Turns
7/60
11/60
15/60
19/60
23/60
27/60
30/60
34/60
37/60
Compressor Connection
(double terminal)
HOW TO ADJUST A MECHANICAL TEMPERATURE CONTROL
Altitude Correction
Scale Guide for Measuring Back of Temperature Control
Bottom of Temperature Control

Bekijk gratis de handleiding van True T-49G-4-HC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkTrue
ModelT-49G-4-HC
CategorieKoelkast
TaalNederlands
Grootte8207 MB