True STA2H-4HS handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 21
7
TRUE
SPEC SERIES: STR, STA & STG HEATED CABINETS
WWW.TRUEMFG.COM
HUMIDIFICATION PROCEDURE
ADJUSTING HUMIDITY
This instruction is TRUE’s recommended procedure for providing
interior humidity control.
The heated cabinet is designed to provide flexibility in desired interior
humidity.
LOW HUMIDITY
A. Positioned on top of the unit and behind the rainshield is the
manual humidity control. To access the humidity control see
instruction above to secure rainsheild in the open position.
B. Turn counterclockwise to ventilate cabinet humidity. (See
photo below)
HIGH HUMIDITY
A. When cabinet contents require higher humidity, close the vent
shown below.
PART FUNCTION
TRUE has designed
this part to assist in
preventing overhead
moisture from
entering into the
food zone of the
cabinet.
Ventilation cap Top of cabinet
ROLL-IN & ROLL-THRU RAMP
INSTALLATION
Once the cabinet is in its final location and level the roll-in ramp can
be installed. The ramp has three slotted holes in back. These slotted
holes slide over three thumb screws located in the front of the
cabinet near the floor.
1 2
3 4
DOOR SWEEP GASKET ADJUSTMENT
To adjust door sweeper gasket, loosen slotted thumbscrews. The
gasket can then be moved up or down and side to side. The gasket
should make some contact with the ramp when the door is closing.
This can be checked by opening up the door 3-4" and allowing
the door to close. This process may have to be done several times
before securing the sweeper gasket bracket. Once gasket is properly
adjusted, tighten slotted thumbscrews. See image 5.