local air conditioner PAC 2020 E / PAC 2620 E
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Notice
Wait for at least 3minutes after maintenance and
repair work. Only then switch the device back on.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Check the on-site fusing.
Observe the operating temperature according to the
chapter Technical annex.
The condensation tank may be full. Empty the
condensation tank, if need be. The error codeFt must not
be indicated on the segment display.
If the device is not starting, have the electrics checked by
a specialist company or by the manufacturer.
The device works with reduced or no cooling capacity:
Check whether cooling mode is selected.
Check the proper fit of the exhaust air hose. In case of
kinks, bends or blockage in the hose, exhaust air cannot
be discharged. Clear the way for the exhaust air.
Check the position of the ventilation flaps. They must be
opened to the maximum.
Check the air filter(s) for dirt. If necessary, clean or replace
the air filter(s).
Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.
Check whether any windows and/or doors of the room are
open. If so, close them. One window has to remain open
for the exhaust air hose nonetheless.
Check the temperature setting at the device. Reduce the
set temperature if it is higher than the room temperature.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
Check whether the ambient temperature equals the target
temperature (in cooling mode). The compressor only
switches on if the ambient temperature is higher than the
target temperature.
The compressor may start up with a delay of 3minutes, as
it is provided with an internal protection against direct
restart.
The device gets very warm, is loud or is losing power:
Check the air inlet and air filter for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by the manufacturer.
The device does not respond to the infrared remote control:
Check whether the distance between remote control and
device is too large and reduce it if necessary.
Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
Check the charging status of the batteries and change
them if required.
If the batteries have just been changed, check them for
correct polarity.
Check whether the remote control is still in standby mode.
Standby mode can be terminated by pressing the Power
button(20) on the remote control.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to the manufacturer for repair.