IX. c - PRINTING:
NO PRODUCT: to add a product name to the cycle data.
NO USER: to add a user names to the cycle data.
PAPER: to receive a cycle data printout.
LABEL: to receive an adhesive lable for the product container.
After printing, press DONE to move on to any remaining probes
which require printing, or to return to the run or idle screens.
IX. d - ADDING PRODUCT TO A CYCLE IN PROGRESS:
Additional products can be added to chill cycles already in
progress when using either the AUTO or MANUAL mode.
For cycles started using either AUTO or MANUAL, simply
insert an available probe into the new hot product to be added.
The chiller will automatically add this probe to the cycle.
This can be repeated as long as there remains an available
probe or zone to use with the new product.
IX. e - FREEZING PRODUCT:
Freezing is done using the MANUAL mode. From the
MANUAL programming screen...
1) Begin by inserting a probe into the product(s) to
be frozen.
2) Press MANUAL then TEMP.
3) Adjust SETTINGS to desired target temp.
4) Select METHOD if other than STANDARD is needed.
5) Select active PROBE. Add operator and product
name if desired.
6) Press START.
NOTE: Upon cycle completion the chiller will automatically
enter “Maintenance Mode” at the target temperature.
-10-
IX. OPERATION (cont’d.)
IX. b - BASIC OPERATION - MANUAL (cont’d):
If parameters are not OK manually program the chill cycle
using the following procedure:
1) Begin by choosing from TEMP, TIME, or PRODUCT.
NOTE: Selecting PRODUCT prompts a list of chill recipes
to appear on the display. Select a product from the list and
press START to start the chill cycle using the parameters set
up for that specic product.
2) Adjust the SETTINGS. These are the desired end-point
temperature (adjustable from +40 to -5°F or chill time
(adjustable from 5-minutes to 6-hours, in 5-minute
intervals).
3) Select a chill METHOD. Choose from STANDARD,
SPEED, ENERGY or DELICATE.
4) Press any active PROBE (indicated by a temperature
displayed below highlighted probe icon) to enter the
PRODUCT and USER names.
5) Press START to begin a chill cycle using the selected
parameters.
NOTE: If programming is stopped at any point prior to pressing
START the control will timeout in 2-minutes. The blast chiller
will rst return to the IDLE MODE and then AUTO start a
chill cycle if one or more probes had been placed in product
above 90°F.
IX. c - PRINTING:
When any probe reaches it’s designated target temperature (or
when the time of any zone elapses), the blast chiller will beep
for 20-seconds indicating that the cycle has completed. The
control display will show DONE beneath this probe or zone.
Press DONE and the the control will display the PRINT screen.
The operator can then select...