Handleiding
Je bekijkt pagina 15 van 18

-14-
VII. a -TROUBLESHOOTING GUIDE
FIND YOUR PROBLEM HERE REMEDY
1. Condensing unit fails to start.
a.Check if cord & plug has been disconnected.
b.Check control temperature setting.
2. Condensing unit operates for prolonged periods or
continuously.
a.Are doors closing properly?
b.Dirty condenser or lter. Clean properly.
c.Evaporator coil iced. Needs to defrost. See instructions for
setting a manual defrost cycle on section VI.c.
3. Food compartment is too warm.
a.Check door(s) and gasket(s) for proper seal
b.Perhaps a large quantity of warm food has recently been
added or the door was kept open for a long period of
time, in both cases, allow adequate time for the cabinet
to recover its normal operating temperature.
c.Control setting too high, readjust per instructions on section
VI.b.
d.Check that condensing coil is clean.
e. Ensure the product is properly loaded and is not blocking
the air ow, see section IV.e.
4. Food compartment is too cold.
a.Perhaps a large quantity of very cold or frozen food has
recently been added. Allow adequate time for the cabinet
to recover its normal operating temperature.
b.Adjust the control to a warmer setting, see section VI.b.
5. Condensation on the exterior surface.
a.Check door alignment and gaskets for proper seal.
b.Condensation on the exterior surface of the unit is perfectly
normal during periods of high humidity.
6. Compressor hums but does not start. a.Call for service.
7. No power to unit
a.Check if cord & plug has been disconnected.
b.Check power supply breaker.
VII. TROUBLESHOOTING GUIDE