PART 1: PLANNING THE INSTALLATION
CAUTION:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never exhaust into a
wall, an attic or a concealed area in the building. This can create a potential hazard.
3. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
4. Locate the cooking area for minimum cross drafts—away from doors and windows, when possible.
5. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep turning
radius as large and as smooth as possible.
6. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint.Then, seal the duct joints with
high quality duct tape.
7. Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes.
8. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise specified.
WARNING: FOLLOWING ARE MANUFACTURER'S SUGGESTIONS. ALWAYS OBSERVE LOCAL
BUILDING CODES.
Hoods installed in custom canopies constructed of combustible materials should be installed with the combustible
material structure at 36” above the cooking surface.Hoods installed in custom canopies constructed of non-combustible
materials, should be installed with the non-combustible material structure at 36” above the cooking surface. Follow all
instructions regarding minimum safe clearances and installation location. Failure to do so may result in a safety hazard or
fire. To reduce the risk of fire use only metal ductwork.
FOR IN-LINE & REMOTE VENTILATORS, DUCT SILENCERS, DAMPERS, AND DUCTING
TRADE-WIND® BBQ Hoods with non-internal motors are designed for use with “in-line” and “remote-mount” ventilators.
When planning for installations using these products, please refer to the Installation Instructions provided with the
ventilator. TRADE-WIND® Duct Silencers are available from your local TRADE-WIND® dealer. When planning for
installation using a duct silencer, please refer to the Installation Instructions provided with the duct silencer.
Given that most installations are different, a back-draft damper is not provided with this unit. TRADE-WIND® back draft
dampers are also available from your local TRADE-WIND® dealer. Always install ventilation products with an approved
wall or roof cap. Duct performance is improved by using round, smooth metal duct work instead of rectangular. Do not
rely on duct tape alone to seal duct joints. Use sheet metal screws as required to support the duct.
PART 2: SECURING THE HOOD
Because the TRADE-WIND® S7200CD Series BBQ Hood was designed for all applications, no mounting holes have been
pre-drilled. This allows for custom applications for mounting. The hood should be attached to the framing through the
top and back, whenever possible.Remove the filters. Mark and drill screw holes through the hood as required.Secure the
hood by driving screws (provided by others) through the screw holes.
NOTE: DRILLING THROUGH STAINLESS STEEL REQUIRES TITANIUM DRILL BITS. BE CAREFUL NOT TO DRILL
THROUGH THE UL LABEL OR INTO THE HOOD’S ELECTRICAL COMPONENTS
MOUNTING HOLES: