7TOPEX.PL
LIQUID GAS BLOWLAMP
44E141
CAUTION: BEFORE USING THE BLOW-LAMP READ
THIS MANUAL CAREFULLY AND KEEP IT FOR FUTURE
REFERENCE.
SAFETY RULES
The blow-lamp can be used only in well ventilated
rooms, away from ammables and in accordance
with valid regulations. Amount of air necessary for
proper burning, that allows to avoid dangerous
concentration of unburnt gas, is 5 m
3
/h.
With the blow-lamp you can use only cartridges
with pressurized butane (propane and butane) with
capacity 190g.
Using dierent cartridge may be dangerous.
Read carefully instructions on liquid gas cartridge
body before installing it in the blow-lamp.
In case of overheating, intermittent or inappropriate
burning, close the blow-lamp valve to avoid re
hazards (1b).
Use the blow-lamp away from ammable materials.
Ensure the valve is closed before carrying the blow-
lamp (1b).
Replace cartridge in well ventilated place, outdoors
if possible, and away from open ame, heat sources,
sparks and ammables. Carry out replacement away
from bystanders.
In case of leak (when you can smell gas) close the
valve and take the blow-lamp to a well ventilated
place, free from ignition sources, i.e. where you can
exactly dene the leakage and remove it.
Check tightness of the blow-lamp if it is possible.
Do not use ame to detect source of escaping gas.
Use soap and water solution for this purpose. Do
not use the blow-lamp when the cartridge mount is
damaged, when there is a leak or the blow-lamp does
not function properly.
Do not make any unauthorized changes or
improvements in blow-lamp construction. Such
changes may be dangerous, void all warranties and
release the manufacturer from responsibility for the
product.
Remove the gas cartridge only when it is completely
emptied.
Do not throw empty gas containers into re.
When using the blow-lamp, and for some time after
the operation is nished, the burner heats many parts
of the lamp. Avoid touching hot parts of the lamp
with your hands.
GB
TECHNICAL PARAMETERS
Temperature [°C] 1350
Gas consumption [g/h] 180
Power [kW] 1,9
Piezo yes
Cartridge
Butane (propane and
butane) pressurized,
190g
TOOL PARTS (1)
Seal a.
Blow-lamp valveb.
Piezo buttonc.
Blow-lamp nozzled.
Liquid gas cartridge casinge.
Liquid gas cartridge (gas cartridge not included in f.
the set)
Base for liquid gas cartridge xingg.
INSTRUCTIONS FOR USE
GAS CARTRIDGE INSTALLATION (gas
cartridge not included in the set)
Ensure the blow-lamp seal is in appropriate posi-1.
tion and in good condition. When there is no seal
or the seal is worn, contact the lamp manufacturer
service department (1a).
Ensure the lamp valve is fully closed (tightened, “-“ 2.
direction) (1b).
Place liquid gas cartridge in the casing (1e).3.
Position the blow-lamp vertically and tighten the 4.
xing of base and the casing (1g).
It will pierce the gas cartridge. After the cartridge 5.
has been pierced do not attempt to remove the
cartridge, even when the valve is opened and gas
does not get out. Contact the lamp manufacturer
service department when necessary.
LIGHTING FLAME AND ITS SIZE
ADJUSTMENT, EXTINGUISHING
FLAME
Open the blow-lamp valve slightly by turning ad-1.
justment wheel in “+” direction (1b).
Light the gas that is coming out of the nozzle end 2.
immediately after opening the valve (1d).
Adjust ame size as required and wait for appro-3.
ximately 1 minute before operating the blow
lamp, while holding the gas container in vertical
position. Do not allow producing intense, yellow
ame.
To switch the blow-lamp o, turn the valve in the 4.
“-“ direction and close it completely (1b).