Faulty electrical connecting leads such as these may
not be used and are highly dangerous due to the in-
sulation damage.
Check electrical connecting leads regularly for dam-
age. Ensure that the connecting lead is not attached
to the mains supply when you are checking it.
Electrical connecting leads must correspond to the
relevant VDE and DIN regulations. Only use con-
necting leads with the code H 07 RN.
The type designation must be printed on the con-
necting lead by regulation.
AC motor
• The supply voltage must be 230 volt ~ / 50 Hz.
• Extension leads up to 20 m in length must have a
cross-section of 1.5 mm
2
. Extension leads whose
length is over 20 m must have a cross-section of
at least 2.5 mm
2
.
• The mains connection is fused with a 16 A slow-
blow fuse.
Please give the following information if you have any
enquiries.
• Kind of current
• Machine type label data
If your are sending back the motor, always send the
complete drive unit with the switch.
Observe the safety instructions!
The product meets the requirements of EN 61000-
3-11 and is subject to special connection conditions.
This means that use of the product at any freely se-
lectable connection point is not allowed.
Given unfavorable conditions in the power supply the
product can cause the voltage to uctuate temporar-
ily.
The product is intended solely for use at connection
points that
a) do not exceed a maximum permitted supply im-
pedance “Z”, or
b) have a continuous current-carrying capacity of the
mains of at least 100 A per phase.
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
13. Disposal and recycling
The equipment is supplied in packaging to prevent
it from being damaged in transit. The raw materials
in this packaging can be reused or recycled. The
equipment and its accessories are made of various
types of material, such as metal and plastic. Defec-
tive components must be disposed of as special
waste. Ask your dealer or your local council.
14. Troubleshooting table
Warning: In the interests of operational safety, always switch off the saw and remove the mains plug before carrying out
maintenance work.
Problem Possible Cause Help
1. Saw blade gets
loose after turning
off the motor
Fastening nut tightened insufciently Tighten fastening nut, M20 left-handed thread
2. Motor does not start a) Failiure main fuse
b) Extension cable defect
c) Connections on the motor or switch defect
d) Motor or switch defect
a) Check the mains fuse.
b) Replace the extension cable
c) Have to checked by an electrician
d) Have to checked by an electrician
3. No motor output,
turns off automati-
cally
a) Cross section of extension cable is too low
b) Overload by dull saw blade
a) See "electric connection"
b) Insert a sharpened saw blade
4. Burns on the cutting
surface
a) Dull saw blade
b) Wrong saw blade
a) Insert a sharpened saw blade
b) Insert correct saw blade