4 TOA Electronics Europe GmbH
Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit.
If they accidentally spill into the unit, this may cause a fire or electric shock.
Do not insert nor drop metallic objects or flammable materials in the ventilation slots of
the unit’s cover, as this may result in fire or electric shock.
When replacing the fuse, be sure to use the supplied one. Using any other fuse than
supplied may cause fire or electric shock.
Be sure to switch off the amplifier's power when replacing the fuse.
Inserting or removing the fuse with the amplifier's power on may cause personal injury.
When Installing the Unit
Do not block the ventilation slots in the unit’s cover. Doing so may cause heat to build up
inside the unit and result in fire.
Avoid installing the unit in humid or dusty locations, in locations exposed to the direct
sunlight, near the heaters, or in locations generating sooty smoke or steam as doing
otherwise may result in fire or electric shock.
Note correct polarity (positive and negative orientation) when connecting the power
supply cord. Reversed polarity connections will cause damage to the unit.
To avoid electric shocks, be sure to switch off the power when connecting the unit.
The VX-3000IM-EB is designed exclusively to be mounted in an equipment rack. Be sure
observe the following instructions when rack-mounting the unit. Failure to do so may cause
a fire or personal injury.
- Install the equipment rack on a stable, hard floor. Fix it with anchor bolts or take other
arrangements to prevent it from falling down.
- The supplied rack-mounting screws can be used for the TOA equipment rack only. Do
not use them for other racks.
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment
this equipment may cause radio interference.
2. GENERAL DESCRIPTION
The isolator manager VX-3000IM-EB is designed to control the transmission path of 8
loudspeaker loops equipped with the isolators VM-300IS-EB. Normally (when no fault is
present) it sends the audio signal into beginning of the loop.
In case of a short circuit on the loudspeaker line, the isolators isolate the defective line from
the proper line. This causes a break of the loudspeaker line. The isolator manager VX-3000IM-
EB detects a break of the loudspeaker line and then sends the audio signal into the beginning
and end of the loop. It indicates the defective line by an LED on the front panel and provides
a control output signal for each faulty line to the VX-3000F.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
CAUTION

Bekijk gratis de handleiding van Toa VX-3000IM-EB, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkToa
ModelVX-3000IM-EB
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1524 MB