55
MIC SP CPU
OFF ON
Failure
Acknowledgment
key
Failure indicator
RM-320FRM-300MF
Buzzer
MIC SP CPU
OFF ON
RM-300MF
Communications Failure indicator
[RM-300MF and RM-320F]
Equipment operation upon failure detection (1)
ThebuzzersoundsandtheFailureindicatorflashesyellow.
In this event, a failure not related to communications has occurred within the system. If the failure is acknowledged
byanysystemcomponent,the buzzerstopsand theyellowFailureindicatorlightswitchesfromflashing to
steady on mode. (Refer to "Failure acknowledgment" on p. 57). Resetting the failure at the VM-3360VA or
VM-3240VAcausestheFailureindicatortogoout.However,ifthecauseofthefailurehasnotbeenremedied,
the unit will again return to failure status. (Refer to "Failure reset operation" on p. 58).
Note
ThefunctionofacknowledgingthespecifiedfailuremustbeassignedtotheRM-320F’skeyinadvanceusing
thesettingsoftware.(Referto"EventSettings"->"RMFunctionKeySettings"->"RM-320FSettings"inthe
separate software instruction manual.)
Equipment operation upon failure detection (2)
The Communications Failure indicator flashes yellow.
A failure has occurred in communications between the RM-300MF and the VM-3240VA or VM-3360VA. The
previous status is automatically restored if communications return to normal.
Bekijk gratis de handleiding van Toa RM-300MF, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Toa |
| Model | RM-300MF |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 19502 MB |
Caratteristiche Prodotto
| Gewicht | 1100 g |
| Breedte | 200 mm |
| Diepte | 82.5 mm |
| Hoogte | 215 mm |
| Kleur behuizing | Wit |