2-13
Chapter 2
INDICATOR STATUS OF REMOTE MICROPHONES
1.14.IndicatorStateattheTimeofEmergencySequencePhaseShift
When the system is set to "Emergency," the emergency sequence phase shift function can be assigned to a
function key.
Pressing the function-assigned key causes the set emergency sequence to shift to the next phase.
The 2 indicators next to the Function key indicate the emergency sequence phase state.
Notes
• Fortheemergencyfunctionsettings,seetheseparateSettingSoftwareInstructions,"BASICSETTINGS."
• For instructions on assigning functions to function keys, see the separate Setting Software Instructions,
"EVENT SETTINGS."
Phase State Indicator
Key ON/OFF Indicator
Function key (Phase shift key)
The meanings of the 2 indicators next to the Function key are as follows:
Indicator Status Meaning
Key ON/OFF Indicator Unlit
When the function key is not pressed
Lights green
When the function key is pressed (as long as it is pressed)
Phase State Indicator Lights green
Emergency sequence Phase 1 is assigned to the function
key.
Flashes green
Emergency sequence Phase 2 is assigned to the function
key.
Unlit
Emergency sequence Phase 3 is assigned to the function
key.