9.5. Removable Terminal Plug Connections
Please note the following points when making connections to the control input, control output, and
speaker output terminals using the supplied removable terminal plugs:
Do not tin stripped wire ends with solder.
Soldered wire ends will be crushed when the terminal plug screws are tightened, leading to higher
contact resistance and potentially resulting in an abnormal rise in the temperature of the connected
parts.
Use AWG 24 – 14 wire (ø0.5 – 1.6 mm solid wire or multi-stranded wire with a cross-sectional area
of 0.2 – 2.0 mm
2
).
Strip the wire end back about 7 mm (0.28").
When connecting 2 wires or a signal cable to a single terminal,
crimp them in an insulated (twin) wire ferrule to prevent their
core wires from being separated from one another. Use a
ferrule of the dimensions shown in the gure at right.
[Plug Connection Procedure]
Step 1. Remove the plug from the terminal.
Step 2. Loosen the terminal screw and insert a wire.
Step 3. Tighten the screw rmly.
Note
Pull on the wire to ensure that it does not
come o󰀨.
Step 4. Insert the plug into the terminal.
Tip
Recommended slotted screwdriver is as follows.
Blade width: about 2.5 mm (0.1")
2.5 mm (0.1")
Shape of bit
a
b
l
2
l
1
Contact
Wire ferrule
b: 0.8 – 1.1 mm (0.03" – 0.04")
l
2: 8 mm (0.31")
Note
Select dimensions “a” and “l1
depending on the wires to be used.
2
2
3
Removable terminal plug
(accessory)
Terminal screw
Tighten Loosen
Slotted screwdriver