Thor H-8HD-EMH handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 32
H-8HD-EMH
6 / 25
Thor Broadcast 2016 Tel: (800) 521-8467 Email: sales@thorfiber.com http://www.thorbroadcast.com
2.2.2 Environment Requirement
Item Requirement
Machine Hall Space
When user installs machine on rack, the distance between 2
rows of machine frames should be 1.2~1.5m and the distance
against wall should be no less than 0.8m.
Machine Hall Floor Electric Isolation, Dust Free, Rack Room with Ventilation
Environment
Temperature
5~40(sustainable )0~45(short time)
installing air-conditioning is recommended
Relative Temperature
20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Power
Device power requires AC power 220V 50Hz. Please carefully
check before running.
2.2.3 Grounding Requirement
It is important to keep this device grounded to ensure all of the modules function
correctly. Correctly grounding the device will also help prevent any electrical
interference, lightening. Etc. Also it helps reject minor interference that may disrupt
the devices ability to function smoothly. General rule of them, make sure the device is
grounded when installing anywhere.
Always use copper wire. When applied correctly the ground must be wrapped well
to ensure maximum conduction so it can reduce any high frequencies. The copper
ground wire should also be as short and thick as possible
Installer must make sure that the two ends of the ground are well conducted and
have appropriate anti-rust properties.
It is prohibited to use any other device as part of the grounding electric circuit.
The area of the conduction between the ground wire and device’s frame should be
no less than 25 .