Handleiding
Je bekijkt pagina 4 van 16

■
The surrounding surfaces must be able to withstand the allowable temperature rise
of 65°C above ambient temperature, as specified in the EN30-1-1 standard and in
accordance with the design of this unit.
■
The temperature of the surrounding surfaces may rise if there are other additional
devices besides the appliance. Check the allowable temperature of the materials used
for the surrounding surfaces to ensure that they meet the requirements of EN30-1-1,
EN1949, EN1645-1, EN1646-1, EN1647 and EN721.
■
All combustible materials such as curtains and shelves must be kept well clear of the
appliance.
■
To ensure correct operation the installation must allow for free exchange of air
between the enclosure and the living environment.
■
Design constraints may dictate additional venting at the front of the installation.
■
This appliance must be earthed.
■
Route cables away from the appliance and other heat sources.
■
Do not allow cables to hang loose into the lower compartment.
Gas specific safety
Risk of serious injury through burning, explosion, clamping, electrocution,
suffocation and poisoning or damage to the product.
■
Ensure that the type of gas and pressure match the specification of the appliance. You
can find the specification on the data badge.
■
Prior to installation, ensure that the local distribution conditions (nature of the gas and
gas pressure) and the adjustment of the appliance are compatible.
■
This appliance is not connected to a combustion products evacuation device. It shall be
installed and connected in accordance with current installation regulations. Particular
attention shall be given to the relevant requirements regarding ventilation.
■
Pay close attention to current regulations on ventilation in the country of use. The
installation must provide for adequate air supply for combustion to the burners, safe
removal of combustion products and avoidance of accumulation of unburned gases.
■
The appliance must be positioned free from draughts, which may effect the
combustion.
■
Maintain provision for the dispersal of unburned gas beneath the appliance. Ensure
any gas dispersal hole is located away from any burner.
■
To ensure correct operation and prevent changes in air pressure affecting appliance
performance, the appliance must be built into a securely fixed self-contained cabinet
which is not connected to externally vented chambers in adjacent furniture, other
than the gas dispersal hole described above.
■
Use only metal gas pipes in accordance with the requirements of EN1949.
■
NEVER use flexible/rubber tubing or hoses to connect gas.
It is recommended to install an over pressure shut off device (OPSO)
downstream of the gas regulator. In case of a regulator failure the OPSO will
immediately stop the gas flow.