MIX 2 series RMG 8 T / RME 8 T actuators
7.2.3 Teach in scenes without telegrams (MIX2 ONLY)
Instead of defining scenes individually by telegram, this can be done in advance in the ETS.
This merely requires the setting of the All channel scene statuses (Scenes parameter page) to
Overwrite at download.
Accordingly, the required status can be selected for each of the 8 possible scene numbers in a
channel (= Status after download parameter).
The scenes are programmed into the device after the download has been completed.
Later changes via teach in telegrams are possible if required and they can be permitted or
locked via a parameter.
7.3 Conversion of percentages to hexadecimal and decimal values
Percentage
value
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Hexadecimal
00
1a
33
4D
66
80
99
B3
CC
E6
FF
Decimal
00
26
51
77
102
128
153
179
204
230
255
All values from 00 to FF hex. (0 to 255 dec.) are valid.