〓〓〓〓 VISCA PROTOCOL 〓〓〓〓
— 21
—
Command type
function
command
CAM_Preset Zoom
Speed Set
Preset Zoom
Speed Set
81 01 7E 01 2B 00 qq FF
qq:Preset Zoom Speed
01~07 default:5
CAM_Preset Speed Adj
Preset Speed
Adj
8x 01 7E 01 1B 0p FF
p: Adjustment of direction
3=down, 2=up
CAM_IR address
IR address
8x 01 06 D8 0p FF
p:IR address 1~4
CAM_Gamma
Gamma set
8x 01 04 5B 0p FF
P:Gamma NO. (0~4)
CAM_2D
Noise Reduction
Direct
8x 01 04 A5 0p FF
(0~0x01)
CAM_3D
Noise Reduction
Direct
8x 01 04 53 0p FF
(0~0x05)
CAM_AT_OnOff
Direct
8x 01 04 C8 0p FF
P: 0 = off
1 = on
CAM_AT_TargetChange
Target change
8x 01 04 CA 0p FF
P:0x02 right move
P:0x03 left move
CAM_TargetLocation
Target location
8x 01 04 CB 0p FF
P: 0:mid 1:left
2:right
CAM_TargetRatio
Target ratio
8x 01 04 CC 0p 0q FF
Pq:(6~20)Human is 1/pq
in the pic
CAM_AT_ChangeTime
Direct
8x 01 04 CD 0p 0q FF
pq:t*10
CAM_AT_BlackBoardM
ode
Direct
8x 01 04 CE 0p FF
p: 1=Enable 0=Disable
CAM_AT_HilightTarget
Direct
8x 01 04 CF 0p FF
p: 1=Enable 0=Disable
CAM_AT_LeftUp_Limit
(preset#251)
Direct
8x 01 04 3F 0p 0F 0B FF
p: 1=Set 2=Call 3=Clear
CAM_AT_RightDown_
Limit(preset#253)
Direct
8x 01 04 3F 0p 0F 0D FF
p: 1=Set 2=Call 3=Clear
CAM_AT_InitialPosition
(preset#255)
Direct
8x 01 04 3F 0p 0F 0F FF
p: 1=Set 2=Call 3=Clear
CAM_AT_BlackBoard
Position(preset#252)
Direct
8x 01 04 3F 0p 0F 0C FF
p: 1=Set 2=Call 3=Clear
CAM_AT_ZoomLock
Direct
8x 01 04 D6 0p FF
p: 1=Enable 0=Disable
CAM_AT_LimitEnable
Direct
8x 01 04 D7 0p FF
p: 1=Enable 0=Disable