22
Advanced Programming Using the MS-4002
Advanced Programming for the MS-4002 has moved from the Internal DIP switches (MS-2002 and previous models) to the
front panel of the unit. Using Figure 6 you can program your MS-4002 with existing and new functionality.
To access Advanced Programming Mode on the MS-4002, do the following:
> Press and hold both Mic Kill and PA for five (5)seconds.
After 10 seconds of inactivity, the system returns back to Operation Mode.
NOTE: A red and green flashing All Talk button signals operation is in Advanced Programming Mode
Each programming function , as well as how to enable and disable the function, is described below.
NOTE: You must be in the Advanced Programming Mode to perform the following configurations.
Call Signal Send and Receive, Channel 1
The Call Signal Send and Call Signal Receive has been combined into one (1) function that is enabled and disabled.
Default Setting: Call Signal Send and Receive, Channel 1 enabled.
To enable the Signal Send and Signal Receive for Channel 1, do the following:
> Press Channel 1 Call button.
The button is backlit with a bright red light. The Signal Send and Signal Receive for Channel 1 is enabled.
To disable the Signal Send and Signal Receive for Channel 1, do the following:
> When lit red, press Channel 1 Call button.
The red back-light dims. The Signal Send and Signal Receive for Channel 1 is disabled.
Figure 6. Advanced Programming Buttons Diagram