If you are using headphones that completely enclose the ears, adjust sidetones as follows:
1. Tap the Headset key to turn the headset microphone on.
2. Tap the channel 1 Talk key to turn it on.
3. While speaking into the microphone, use a small flat-bladed screwdriver to adjust the channel 1 Talk key to turn it so
you hear your voice at an acceptable level in the headphones.
4. Tap the channel 1 Talk key to turn it off when finished.
5. Tap the channel 2 Talk key to turn it on, and adjust the channel 2 sidetone as for channel 1.
6. Tap the channel 2 Talk key to turn it off when finished.
To set channels 3 and 4, do the following:
> Repeat steps 1 through 6, above.
Voice-Activated Microphone (Vox) Setup
If you are going to use Vox, you must adjust its level for proper operation. If the Vox level is too low, room noise activates the
microphone. If the Vox level is too high, the microphone does not activate when you begin talking.
To check and set the Vox level, do the following:
1. If you are using a headset, tap the Headset key twice to turn on headset Vox.
OR
If you are using a panel microphone, tap the Panel Mic key twice to turn on panel mic Vox.
Whichever key you tap, it will glow orange when the microphone is off and flickers or turn green when the sound is
picked up by the microphone.
2. Position the microphone at its normal operation location.
If you are using a headset, put the headset on and position the microphone about three fingers length from your
mouth.
3. Insure that background noise is at the normal operating level.
Do not speak into the microphone.
4. If the Headset or Panel Mic key is constantly glowing orange, turn the Vox trimmer clockwise until the key begins to
flicker green (mic activating), then turn the trimmer slightly back in the counterclockwise direction until the Panel
Mic key just returns to steady orange (mic off).
If you are wearing a headset, make sure that breathing and movement do not cause the Panel Mic key to flicker green.
If they do, adjust the Vox control slightly more in the counterclockwise direction to eliminate this.
5. Speak into the microphone in a normal voice, and verify the headset key immediately turns green when you talk.
If the key does not turn green, move the microphone closer to your mouth.
NOTE: If you are still unable to get satisfactory results, it may be that the microphone does not have the directional
characteristics required for the noise level in the room. A directional, or cardioid, microphone is
recommended when using Vox.
6. To return the MS-4002 to normal operation, tap the Mic Kill key.