2.
3.
Note: During normal operation, the inlet valve shall be set in the status
of “open”.
Insert the supply plug into the socket, the two indicator lights will be on at
the same time..
This machine can automatically control the temperature. When the water
temperature inside the machine has reached the set temperature (It is set
to 75), it will be turned off automatically, and step into the status of
thermal insulation; when the water temperature is decreased to a certain
point, it will be turned on automatically to restore the heating, and the use
of hot water will not be interrupted. When the heater is switched off auto-
matically, the heating indicator will turn off.
4. Operating Of The Unit
6
ECO
MODE
6
5
2
1
3
4
“1” button is for frequency switch. When press firstly, display screen “4” will show
the six frequency option ( index number “1” means 1200W, index number “2”
means 2000W , index number “3” means smart control energy saving mode, index
number “4” means energy saving mode, index number “5” means high temperature
sterilization mode , index number “H” means the reservation mode. ) the six display
number will be displayed back and forth.
"2" is the on/off button, when press , water heater start working,display screen will
be lighted up. Then press again, electricty will be cut off, and display screen will be
shut down.
“3” is for temperature adjustment knob with 360 °loop.Temperature increases by
clockwise rotation, and decreases if anticlockwise. During the rotation , desplay
screen 4” will change accordingly. When temperature setting meets customers‘
requirements, stop rotating and display screen “4” will flash for around 3 seconds,
which means temperature has been setted successfully. After flashing ,display
screen “4” value will return to current inner water heater temperature. After the
smart control energy saving mode, the knob can not be adjusted. When entering
the appointment mode, the knob can adjust the appointment time.
"6" is for frequency display.
If number " 1" comes out , it means 1200W(only one tank is heating ) ;
If number "2" comes out , it means 2000W (the two inner tank has been being
heated up );

Bekijk gratis de handleiding van Teka SHS 100, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkTeka
ModelSHS 100
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5373 MB

Caratteristiche Prodotto

Soort bedieningDraaiknop
Kleur van het productWit
Ingebouwd displayJa
Gewicht38380 g
Breedte570 mm