2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times 
the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical 
department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
•  The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
• The ventilation machinery and outlets are operating adequately and are not obstructed;
• If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
• Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
•  Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which 
may corrode refrigerant containing components, unless the components are constructed of materials which are inherently
resistant to being corroded or are suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a 
fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily 
dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary 
solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
• those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
• that there no live electrical components and wiring are exposed while charging, recovering or purging the system;
• that there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 9 m².
Do not install the unit in a place where inflammable gas may leak.
NOTE!
The manufacture may provide other suitable example or may provide additional information about the refrigerant odour.