  Page 16 of 16                DPP960-xx-3,  23425 issue 03, April 2013 
Product HANDBOOK 
DPP960
-
xx
-
3
Mechanical Outline Drawings: 
Front panel indicators:   
DC ON - The Green LED is on when the output voltage is >75%.    
DC LOW - The red LED is on when the output voltage is between 70 – 90%. 
The output can be increased by turning the front panel potentiometer clockwise, turning the potentiometer 
counter clockwise will decrease the output. 
Adjusting output voltage beyond the stated range may cause overvoltage protection (OVP) to clamp the 
output. To reset for normal operation simply adjust the potentiometer to reduce the output voltage to within its 
range (see table above) 
Power ready signal (Rdy) 24V model only. 
Contact closed at start up – threshold voltage 17.6 – 19.4Vdc 
Contact electrical isolation  500Vdc 
Contact rating 60Vdc/0.3A 
Weight: DPP960-xx-3 weighs 3400g 
TDK-Lambda UK Ltd  
Kingsley Avenue, Ilfracombe 
Devon, EX34 8ES 
Telephone - Sales and Service +44 (0)1271 856666 
Head Office and Works +44 (0)1271 856600 
Facsimile +44 (0)1271 864894 
WEBSITE: 